Grounding System

Grounding System

Direct earth grounding of the antenna and the Lightning Protector is necessary to protect
the installation from lightning and the build-up of static electricity.

The grounding system must satisfy the following requirements:

•

The antenna mast, RoamAbout AP, and RoamAbout Lightning Protector must be
connected to the same earth ground using an equipotential bonding conductor.

•

The antenna and the mounting structure require a separate earth ground connection.
Check with a certified antenna installer to make sure the antenna is properly grounded.

•

Ensure that the cable between the antenna and Lightning Protector is at least 0.9 meters
(3 feet) away from high-voltage or high-current cable.

•

A good electrical connection must be made to one or more ground rods, using at least
a 10AWG ground wire and noncorrosive hardware.

•

The grounding system must comply with electrical codes and safety standards that
apply in your locality.

Have a qualified electrician verify that your RoamAbout outdoor installation is properly
grounded.

CAUTION: The antenna mast, RoamAbout AP, and lightning protector
must be connected to the same earth ground (with separate grounds),
using an equipotential bonding conductor. A good electrical connection
should be made to one or more ground rods using at least a 10AWG
ground wire and non-corrosive hardware. The grounding system must
comply with the National Electrical Code and safety standards that
apply in your country. Always check with a qualified electrician to
determine whether your outdoor installation is properly grounded.

CAUTION: A properly installed safety grounding system is necessary to
protect your RoamAbout outdoor installation from lightning strikes and
static electricity build-up.