Maintenance

WARNING

Hot exhaust system components may ignite
gasoline vapors even after the engine is stopped.
Hot particles exhausted during engine operation
may ignite flammable materials. Fire may result
in personal injury or property damage.

Do Not refuel or run engine unless spark arrester
is installed.

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Wait for muffler to cool.
3. If any breaks in the screen or welds are observed,

replace arrester.

4. If plugging of the screen is observed, remove

arrester and shake loose particles out of the
arrester and clean screen with a wire brush (soak
in solvent if necessary). Reinstall arrester on
exhaust outlet.

Thread Locking Adhesives

Thread locking adhesives such as “Loctite 242”
or “Fel-Pro, Pro-Lock Nut Type” are used on the
following fasteners:

ROPS spring pin housing.

Hydro pump control arm, linkage bolt, and
attachment bolt.

Hydro cooling fan screw.

Hydro park brake cable anchor mounting bolt

Sheave and clutch retaining bolt in the end of
engine crankshaft.

Thread locking adhesives are required for some
hardware on engines — see the Engine manual.

Copper-Based Anti-seize

Copper-based anti-seize is used in the following
location:

On threads of Blade Bolts. See Check Mower
Blades
section.

Dielectric Grease

Dielectric grease is used on all blade type electrical
connections to prevent corrosion and loss of contact.
Dielectric grease should not be applied to sealed
connectors.

Adjustments

Note: Disengage PTO, shut off engine, wait for
all moving parts to stop, engage parking brake, and
remove key before servicing, cleaning, or making any
adjustments to the unit.

CAUTION

Raising the mower deck for service or
maintenance relying solely on mechanical
or hydraulic jacks could be dangerous. The
mechanical or hydraulic jacks may not be enough
support or may malfunction allowing the unit to
fall, which could cause injury.

Do Not rely solely on mechanical or hydraulic
jacks for support. Use adequate jack stands or
equivalent support.

Deck Leveling

1. Position the mower on a flat surface.
2. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

3. Check the tire pressure in the drive tires. Proper

inflation pressure for tires is 13 psi (90 kPa).
Adjust if necessary.

4. Position the transport lock in the latching

position.

5. Push the foot pedal all the way forward and the

deck will latch at the 5 1/2 inch (14 cm) transport
position (Figure 26).

Figure 26

1.

Foot lever

3.

Transport lock

2.

Height of cut pin

6. Insert the height adjustment pin into the 3 inch

(7.6 cm) cutting height location.

39