1 / INSTALLING YOUR APPLIANCE

These hobs must be connected to the power
grid via an all-pole cut-off device that com-
plies with installation regulations in effect.
A disconnection device must be incorporated
into the fixed wiring.

Your appliance must be positioned so that the
power plug is accessible.
When power is first supplied to your hob, or after
an extended power outage, an indicator light will
appear on the control panel. It automatically
disappears after approximately 30 seconds, or
as soon as any touch control on the control
panel is pressed. (This display is normal and, if
needed, serves as an indication to the after-
sales service staff. In all cases, the user of the
hob should disregard it).

HOOK-UP

N

e

u

tra

l

E

art

h

Ph

ase

N

L

Green/yellow

Blue

Black-grey

Brown

•220-240V ~ hook-up

32A

Separate the two phase wires (L1 and L2)
before hooking up.

Neutral

Earth

Phase

N

L1 L2

Blue

Green/yellow

Black-grey

Brown

When connecting a three-phase 400 V 2N, if
your hob malfunctions, check that the neu-
tral wire is properly connected.

•400V 2N

~

- 16A hook-up

Separate the wires before hooking up.

Neutral

Earth

Phase

N1

L1 L2

Blue

Green/
yellow

Black-grey

Brown

•2x230V 2L+2N

~

- 16A hook-up

N2

Advertising