CLEARANCES (cont.)

figure 6a - Mantel Clearances with Standard hood

figure 6b - Mantel Clearances with Optional Extended hood

MANTEL

STANDARD
HOOD

17 ½”

10”

12”

MAX

42”

MIN.

(CEILING TO
TOP OF HOOD)

4 ½”

MIN.

FIREBOX
FACE

84”

MIN.

(CEILING TO FLOOR)

CEILING

COMBUSTIBLES

ALLOWED

3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREPLACE

8”

6 ½”

5”

3 ½”

1 ½”

0”

6 ½”

9”

11”

13”

15”

MANTEL

13”

10”

12”

MAX

42”

MIN.

(CEILING TO
TOP OF HOOD)

8”

MIN.

84”

MIN.

(CEILING TO FLOOR)

CEILING

COMBUSTIBLES

ALLOWED

22”

8”

20”

6 ½”

18”

5”

16”

3 ½”

14 ½”

2 ½”

24 ½”

0”

FIREBOX
FACE

EXTENDED HOOD
(VB4H SERIES)
(NOT AVAILABLE ON
PENINSULA OPEN END)

3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREPLACE

Ceiling Clearances: The ceiling height should not be less than 42"

from the top of the hood. See figures 6a and 6b.
Mantel Clearances:
Vent free fireplace models must use the hood

supplied with the fireplace, or one of the optional hood kits avail-

able for each model. If a combustible mantel is installed, it must

meet the clearance requirements detailed below.
Leave furniture and other combustible items at least 36" away from

the front openings of the fireplace.

Do not attach combustible material to the mantel of your fireplace.

This is a fire hazard.

figure 7

No greeting cards, stockings or ornamentation of any type should

be placed on or attached to the fireplace. This is a heating appliance.

The flow of heat can ignite combustibles.

figure 8

COMBUSTIBLE MATERIALS