Peak Hold:

Ranges:

frequency

Accuracy

66.00V, 660.0V, 750V

50 to 500 Hz

± (3.0% rdg + 200 dgts)

** Frequency: 10% to 100% of voltage range
AC coupled TRMS: 5% to 100% of range
Crest factor: ≤ 3
Input impedance: 660 mV: >100 MΩ; 6.6 V:10 MΩ; 66 V to 750 V: 9.1 MΩ
Overload protection: 1000 VDC or 750 VAC rms

AC CURRENT TRUE RMS

Ranges:

frequency

Accuracy

66.00A*

50 to 60 Hz

± (2.0% rdg + 10 dgts)

66.00A*

61 to 400 Hz

± (3.0% rdg + 10 dgts)

660.0A

50 to 60 Hz

± (2.0% rdg + 10 dgts)

660.0A

61 to 400 Hz

± (3.0% rdg + 10 dgts)

1000 A

50 to 60 Hz

± (2.5% rdg + 10 dgts)

1000 A

61 to 400 Hz

± (3.5% rdg + 10 dgts)

Frequency**

50 to 1kHz

± (0.1% rdg + 5 dgts)

Peak Hold:

Ranges:

frequency

Accuracy

66.00A*, 660.0A,1000A

50 to 400 Hz

± (3.0% rdg + 200 dgts)

* ACD-3300 IND only
** Frequency: 10% to 100% of current range
AC coupled TRMS: 5% to 100% of range
Crest factor: ≤ 3
Overload protection: 1000A AC

DC CURRENT (ACDC-3400 IND only)

Range

Accuracy

660.0A

± (2.0% rdg + 5 dgts)

1000A

± (3.0% rdg + 5 dgts)

Overload protection: 1000A DC