Amprobe AU92 Automotive-Multimeter User Manual

Page 14

Advertising
background image

12

ELECTRICAL SPECIFICATION Accuracy at 23 °C ± 5 °C, < 75% R.H.

DC VOLTS
Ranges:

400 mV, 4 V, 40 V, 400 V, 600 V

Accuracy:

±(1.0% rdg + 2 dgts)

Resolution:

0.1 mV

Input impedance:

400 mV: >100 MΩ; 4 V:10 MΩ; 40 V ~ 600 V: 9.1 MΩ

Overload protection:

600VDC or AC rms

AC VOLTS
Ranges:

400 mV, 4 V, 40 V, 400 V, 600 V

Range:

Accuracy:

400 mV (50 ~ 100 Hz)

±(2.0% rdg + 5 dgts)

4, 40, 400, 600 V (50 ~ 500 Hz)

±(2.0% rdg + 5 dgts)

Resolution:

0.1 mV

Input impedance:

400 mV: >100 MΩ; 4 V: 10 MΩ; 40 V ~ 600 V: 9.1 MΩ

Overload protection:

600 VDC or AC rms

DC CURRENT
Ranges:

400 µA, 4000 µA, 40 mA, 400 mA, 10 A

Range:

Accuracy:

400 µA to 400 mA ranges

±(2.0% rdg + 2 dgts)

10 A range

±(3.0% rdg + 3 dgts)

10A input: 10 A for 60 seconds maximum followed by a 10 minutes cooling period
Resolution:

0.1 µA

Voltage burden:

0.2 V on 400uA, 40mA ranges ;

2V on 4000 uA, 400 mA ranges

Input protection:

0.5 A / 500V fast blow ceramic fuse (FP520)

10 A / 500 V fast blow ceramic fuse (FP540)

AC CURRENT
Ranges:

400 uA, 4000 uA, 40 mA, 400 mA, 10 A

Range: (50 ~ 500 Hz)

Accuracy:

400 uA to 400 mA ranges

±(2.5% rdg + 5 dgts)

10 A range

±(3.5% rdg + 5 dgts)

10A input: 10 A for 60 seconds maximum followed by a 10 minutes cooling period
Voltage burden:

see DC Current

Input protection:

see DC Current

Advertising