Ohms, Frequency – Amprobe PM51A User Manual

Page 13

Advertising
background image

11

Ohms

Range

Accuracy

400.0 #

&(1.5%+6 dgt)

4.000 K#, 40.00 K#, 400.0 K#

&(1.0%+4 dgt)

4.000 M#

&(1.5%+4 dgt)

40.00 M#

&(2.5%+4 dgt)

Open Circuit Voltage: 0.4 V dc typical

Frequency

Range

1

Accuracy

400 Hz, 4 kHz, 40 kHz, 400 kHz, and 1 MHz

&(0.5%+4 dgt)

1

Specified at Input Voltage < 20 V ac rms Input Signal: Sine-wave, or Square-wave with duty

cycle > 40% & < 70%
Sensitivity (V-peak):
5 Hz - 100 kHz

: > 1.3 Vp

100 kHz - 500 kHz : > 2.2 Vp

500 kHz - 1 MHz : > 4.2 Vp

Diode Tester

Test Current (Typical): .25 mA

Open Circuit Voltage: 1.6 V dc

Audible Continuity Tester

Open Circuit Voltage: 0.4 V dc typical

Audible Threshold: between 10 # and 120 #