Amprobe TMD-10 Dual-Temperature-Meter User Manual

Page 6

Advertising
background image

5

SyMboLS

�

Refer to the manual

�

Complies with EU
directives

�

Conforms to relevant
Australian standards.

�

Do not dispose of this
product as unsorted
municipal waste.

�

Warning and Precautions

The bead thermocouples supplied with the meter are not intended for

•

contact with liquids or electrical circuits.
Do not mix thermocouple types.

•

Match the polarity of the adapter to the polarity of the thermocouple

•

inputs.

UNPACkINg AND INSPECTIoN
Your shipping carton should include:

1 TMD-10 temperature meter
2 K-type thermocouples
1 9 volt battery
1 Manual

If any of the items are damaged or missing, return the complete package to
the place of purchase for an exchange.

INTRoDUCTIoN
The TMD-10 is a dual input temperature measurement meter using Type K or
Type J thermocouples.

oPERATIoN

Press the

1.

�

button to turn power on or off

Set the Function Switch to °C or °F.

2.

Select thermocouple type (K / J) and connect the thermocouple(s) to the

3.

T1 or T2 input.

�

Do not mix thermocouple types.

�

Match the polarity of the adapter to the polarity of the thermocouple

input.

Expose the thermocouple(s) to the temperature(s) to be measured.

4.

Read the LCD display.

5.

Advertising