Amprobe INSP-3 Wiring-Inspection-Tester User Manual

Page 17

Advertising
background image

10

11

smaller than 14 gauge wire and not longer than
4 feet.

Large power disturbances or spikes may cause
erratic readings.

SPECIFICATION

Load: Constant 0, 10,15 or 20 AMP simulation
regardless of line voltage
Operating Voltage: 95-140V AC
Power: 9V Alkaline Battery
Fuse: ½ Amp, 125V. Not user replaceable.
GFI Trip: 6.0 mA nominal to trip GFI, 30 mA to trip RCD
AFCI Trip: Up to 8, 120 Amp pulses within ½ second
period
Operating Temperature: 0°C to 50°C ( 32°F to 120°F)
Accuracy: +/- 2%, +/- 2 digits.

MAINTENANCE AND REPAIR

If there appears to be a malfunction during the
operation of the meter, the following steps should
be performed in order to isolate the cause of the
problem.

1. Check the battery. Replace the battery

immediately when the unit doesn’t turn ON.

2. Make sure you use the power cord provided

with the unit