Amprobe VPC-20N Voltage-Continuity-Tester User Manual

Page 2

Advertising
background image

To check for the presence of AC electrical voltage in a conductor
or outlet:
1. Touch the bottle shaped protrusion of the probe tip to the hot
conductor, or insert the probe tip into all the outlet holes. The probe will
distinguish between hot and neutral.
2. If AC electrical voltage is present and this is the hot side, the non-
contact probe LED will illuminate.

Specifications

Function

Range

Accuracy (%rdg. + digits)

V AC (50Hz~400Hz)

600V

+(2.9%+8)

V DC

600V

+(1.5%+2)

Continuity test: Audible threshold 0~10K

W, Continuity beeper 2KHz.

Overload protection: AC/DC 600V

Dimension/wt.: 215x96.3x37.5mm/312g

Display: Large 1999 count LCD display with function and high voltage
warning indication.
Maximum Voltage Between any Terminal and Earth Ground:
600V DC; 600V AC RMS, Over-voltage Category III
Safety: UL Listed; 61010B-1: For use in Over-Voltage CAT III, 600V
environments
EMC Regulations: EN50081-1, EN50082-1
Pollution Degree: 2
For indoor use only.
Polarity
: Automatic, (-) negative polarity indication.
Over-range: “1” mark indication
Low battery indication: The “BAT” is displayed when the battery voltage
drops below the operating level.
Measurement rate: 2 times per second, nominal
Continuity test: Audible threshold 0 -10KW, Continuity beeper 2KHz
Input Impedance: 400KW
Non-contact AC Voltage Sensitivity: 100 to 600V (50/60 Hz)
Non-contact AC Voltage detection distance: <0.5” of NCV sensor
Temperature: Operating: 5°C (41°F) to 40°C (104°F)
Storage:-30˚C to +60˚C
Altitude: Operating: 2,000m; Storage: 10,000m
Relative Humidity: 80% for Temperature up to 31˚C decreasing
linearly to 50% RH at 40˚C
Battery Type: AA (2); NEDA 15F or IEC R6

Replacing the Batteries
If the sign “BAT” appears on the LCD, it indicates that the batteries should be
replaced. Remove screws on the back cover and open the case. Replace the
exhausted batteries with new batteries.

(AA (2); NEDA 15F or IEC R6)

Disconnect probes from Voltage
Do Not over-tighten screws

2xAA

WARRANTY
Congratulations! Your new instrument has been quality crafted according to quality
standards and contains quality components and workmanship. It has been
inspected for proper operation of all of its functions and tested by qualified factory
technicians according to the long-established standards of our company.

Your instrument has a limited warranty against defective materials and/or
workmanship for one-year from the date of purchase provided that, in the opinion
of the factory, the instrument has not been tampered with or taken apart.

Should your instrument fail due to defective materials, and/or workmanship
during this one-year
period, a no charge repair or replacement will be made
to the original purchaser. Please have your dated bill of sale, which must
identify the instrument model number and serial number and call the number
listed below:
Repair Department
ATP – Amprobe, TIF, Promax
Miramar, FL
Phone:

954-499-5400

800-327-5060
Fax : 954-499-5454
Website:

www.amprobe.com

Please obtain an RMA number before returning product for repair.

Outside the U.S.A. the local representative will assist you. Above limited warranty
covers repair and replacement of instrument only and no other obligation is stated
or implied.

Miramar, FL

Tel: 954-499-5400 • Fax: 954-499-5418

www.Amprobe.com

P/N: ATP 0403D

printed in China

Advertising