Termination control connector j4, Led description – Avago Technologies LSI53C120 User Manual
Page 25

LSI20101/LSI20102 SCSI Bus Boards
17
Connecting the Disable SE-A TERM or Disable SE-B TERM pins on J5
to ground turns off the onboard termination for the indicated physical bus.
See
4.4.4 LEDs and Connector J4
The LSI20102 board contains three LEDs: one bus activity LED and two
SCSI TERMPWR status LEDs.
One green LED reflects the status of the SCSI bus busy signal.
Two yellow LEDs, one for each bus, indicate when TERMPWR is shorted
to ground. For instance, if TERMPWR is grounded somewhere in the
subsystem while TERMPWR is supplied by the board (when U8 switches
SW1 and/or SW2 are ON), the LED will light. See
Table 10
Termination Control Connector J4
J4-Pin Number
Signal Name
1
Disable SE-A TERM
2
GND
3
Disable SE-B TERM
4
GND
Table 11
LED Description
LED
Color/Condition
Description
CR1
Yellow/ON
DIFF, TERMPWR shorted to ground
CR7
Green/ON
A-Side, BUSY (SCSI active on Side-A)
1
1. If the SCSI busy signal is active on A-side, it is also active on B-side and vice
versa.
CR10
Yellow/ON
SE, TERMPWR shorted to ground