Starting the data analyzer, Stopping the data analyzer, Returning to the main menu – ProSoft Technology MVI71-GSC User Manual

Page 40

Advertising
background image

MVI71-GSC ♦ PLC Platform

Diagnostics and Troubleshooting

Generic Serial Communication Module

Page 40 of 82

ProSoft Technology, Inc.

January 31, 2008

Starting the Data Analyzer

Press [B] to start the data analyzer. After the key is pressed, all data transmitted
and received on the currently selected port will be displayed. An example display
is shown below:

The Data Analyzer displays the following special characters:

Character Definition

[ ]

Data enclosed in these characters represent data received on the port.

< >

Data enclosed in these characters represent data transmitted on the port.

<R+>

These characters are inserted when the RTS line is driven high on the port.

<R->

These characters are inserted when the RTS line is dropped low on the port.

<CS>

These characters are displayed when the CTS line is recognized high.

_TT_

These characters are displayed when the timing mark interval has been reached.
This parameter is user defined.

Stopping the Data Analyzer

Press [S] to stop the data analyzer. Use this option to freeze the display so the
data can be analyzed. To restart the analyzer, press [B].

Important: When in analyzer mode, program execution will slow down. Only use this tool during a
troubleshooting session. Before disconnecting from the Config/Debug port, please press [S] to stop
the data analyzer, and then press [M] to return to the main menu. This action will allow the module
to resume its normal high speed operating mode.

Returning to the Main Menu

Press [M] to return to the Main Menu.

Advertising