Td-9, Td-4 – Roland BT-1 Bar Trigger Pad User Manual
Page 10

Trigger Parameter Settings for the Drum Sound Module
10
TD-9
Trig Type
PD8
Sensitivity
12
Threshold
8
Scan Time
1.6
Retrig Cancel
4
Mask Time
8
XTalk Cancel
25
Rim Gain
1.0
XTalk Cancel
20–40
* When using a BT-1 on a V-Drums pad,
set this XTalk Cancel parameter for that
V-Drums pad.
* The “KIK” and “RDB” trigger inputs are not supported.
* The BT-1 will operate as the rim trigger of the pad. No sound or
control function (e.g., pad pattern) should be assigned to the
“head” of the input the BT-1 is connected to.
TD-4
Pad Type
PD-8
Sensitivity
12
Threshold
8
Scan Time
1.6 ms
Retrig Cancel
4
Mask Time
8 ms
Xtalk Cancel
25 %
Rim Gain
1.0
Xtalk Cancel
20–40 %
* When using a BT-1 on a V-Drums pad,
set this Xtalk Cancel parameter for that
V-Drums pad.
* The “KIK”, “T1”, “T2”, and “T3” trigger inputs are not supported.
* The BT-1 will operate as the rim trigger of the pad. No sound or
control function (e.g., pad pattern) should be assigned to the
“head” of the input the BT-1 is connected to.