Installation – England's Stove Works TRANQUILITY 17VL User Manual

Page 14

Advertising
background image

Page | 14

INSTALLATION

Mobile Home Installation 

 The wood stove MUST be secured to the floor of the mobile home using lag bolts and the holes 

provided in the bottom of the unit for this 
purpose. 

 The wood stove must be connected to the 

chimney system with double wall chimney 
connector which is UL listed (ULC if Canada) 
for use in mobile and manufactured homes. 

 Carefully follow all clearances listed in the 

appropriate section of this manual AND follow 
the venting manufacturer’s minimum 
clearance requirements.  Similarly, be certain 
the venting system used is approved for 
mobile home use. 

 Installation must be in accordance with 

Manufacturers Home & Safety Standard (HUD) 
CFR 3280, Part 24 as well as any applicable local codes. 

Outside Combustion Air 

 The use of outside combustion air is mandatory when installing this wood stove in a mobile or 

manufactured home. 

 The outside air connection pipe protrudes from the bottom center of the stove; a kit is available 

from England’s Stove Works, Inc. designed for connecting this unit to outside combustion air. [Part 
No. AC‐OAK5] 

If it is not feasible to use the AC‐OAK5 outside air hookup kit in your stove installation, other 

materials may be used, provided the following rules are followed: 

o

The pipe used for outside air hookup must be metal, with a minimum thickness of .0209in. 
(25 gauge mild steel) or greater and an inside diameter of approximately 4.25in. 

o

Keep pipe runs short and use a mechanical fastener at each pipe joint. 

o

A screen or other protection device must be fitted over the outside air termination point to 
prevent rain, debris and nuisance animals from entering the piping system.  Inspect the 
outside combustion air inlet for block and debris monthly. 

WARNING 

DO NOT INSTALL IN A SLEEPING ROOM. 

CAUTION 

THE STRUCTURAL INTEGRITY OF THE 

MANUFACTURED HOME FLOOR, WALL AND 

CEILING/ROOF MUST BE MAINTAINED. 

Caution 

NEVER draw outside combustion air from: 

Wall, floor or ceiling cavity or 

enclosed space such as an attic, garage or crawl 

space. 

Joist Shield/Firestop

Mobile Home Approved Double 

Wall Chimney Connector

Roof Flashing and Storm Collar

Chimney Cap/Spark Arrestor

Use silicone to create a vapor 
barrier where the chimney passes 
through to exterior. 

Class A Chimney System 