In this mode, the modeling light is set to 100W and the „Flash
Check“ function, which turns off the modeling light after flas
-
hing and turns it back on as soon as the unit has recharged
and is ready to flash again, is activated.
Â
Connect the
Expert D
compact flash unit to one of the pow
-
er jacks on the Power Max L and switch the Power Max L on
via the power switch.
Â
Switch on the
Expert D
and press its SLAVE button for at
least 3 seconds: the flash unit now switches to the Power
Max mode which is then confirmed by a beep tone. The
selected output and „bat. “ blink alternately in the perfor
-
mance display to indicate the activated Power Max mode.
Additionally, the LED „FULL“ blinks on the flash unit indi
-
cating that the modeling light is dimmed to a fixed, non-
proportional 100W.
Â
After connecting and switching the first
Expert D
, you can
add – if needed – a second unit and also switch it to the
Power Max mode as indicated above.
The
Expert D
flash units stay in this mode once it is activa
-
ted, even after they are switched off. No damage occurs if the
Expert D
are operated on a normal power supply when in
Power Max mode. To return to a full modeling light, the SLAVE
button must be pressed again for 3 seconds – the Power Max
mode is deactivated.
ATTENTION!
Expert D flash units prior to serial number
1303H0030101340
(Expert D 500) and
1303H0030100461
(Expert D 1000) do not
function in connection with the Power Max L and need a new
operating software.
Please contact your Hensel service at the Wuerzburg headquar
-
ters and have the update done there.