Viewing active drive faults, Rebooting the drive, Resetting faults – Emerson 400518-01 User Manual

Page 60

Advertising
background image

48

Safety Information

Product Overview

Installation

Diagnostics

Options and
Accessories

Specification

Figure 45:

Active Drive Faults Detected Dialog Box

Resetting Faults

Some drive faults are automatically reset when the fault condition is cleared. Other faults require drive logic power

to be cycled or the drive to be “rebooted”. If you wish to continue working in the PowerTools Pro software without

resetting the fault, click the Ignore Fault button.
To reset faults that can be reset with the Reset Faults button, simply click the Reset Faults button in the Drive Faults

Detected dialog box or push the Reset button on the front of the drive where the fault occurred.

Viewing Active Drive Faults

To view all active drive faults, select the View Faults command from the Device menu or by clicking on the View

Faults button on the toolbar. The dialog box displayed is the same as Active Drive Faults Detected dialog box

described above.

Rebooting the Drive

To reboot the drive, cycle power or select the Reboot Drive command from the Device menu. This command reboots

the drive attached to the active Configuration Window.