RF-Links 120mW Wideband Microwave Amplifier (50 MHz-6 GHz) User Manual
Page 2

Parameter
Min.
Typ.
Max.
Unit
Condition
Small Signal Gain
19.0
20.5
22.0
dB
850 MHz
18.3
19.0
21.5
dB
1950 MHz
14.5
15.5
17.5
dB
6000 MHz
Output Power at 1 dB Compression
20.5
dBm
850 MHz
19.0
20.0
dBm
1950 MHz
Third Order Intercept Point
38.5
dBm
850 MHz
33.0
35.0
dBm
1950 MHz
Bandwidth
3000
MHz
Min. 10 dB return loss (typ.)
Input Return Loss
10.0
13.0
dB
1950 MHz
Output Return Loss
10.0
14.0
dB
1950 MHz
Reverse Isolation
23.3
dB
1950 MHz
Noise Figure
3.9
4.9
dB
1950 MHz
Device Operating Voltage
4.75
5.0
5.25
V
Device Operating Current
60.0
75.0
92.0
mA
Thermal Resistance
69.9
°C/W
junction - lead
Typical Performance at Key Operating Frequencies (0.5GHz to 3.5GHz Application Circuit)
Specification
Parameter
Min.
Typ.
Max.
Unit
Condition
21.1
dB
50 MHz
20.9
dB
100 MHz
20.8
dB
200 MHz
20.8
dB
500 MHz
20.8
dB
850 MHz
20.1
dB
1950 MHz
19.8
dB
2500 MHz
18.7
dB
3500 MHz
Small Signal Gain
17.8
dB
4000 MHz
36
dBm
50 MHz
37.8
dBm
100 MHz
37.5
dBm
200 MHz
38.6
dBm
500 MHz
39.2
dBm
850 MHz
34.9
dBm
1950 MHz
32.8
dBm
2500 MHz
Output Third Order Intercept Point
29.4
dBm
3500 MHz