RF-Links 1000mW Wideband Microwave Amplifier (50 MHz–6 GHz) User Manual
Page 2

Typical Performance at Key Operating Frequencies (0.5GHz to 3.5GHz Application Circuit)
Specification
Parameter
Min.
Typ.
Max.
Unit
Condition
35
dB
50 MHz
34
dB
100 MHz
33
dB
200 MHz
36
dB
500 MHz
33
dB
850 MHz
2
dB
1950 MHz
30
dB
2500 MHz
28
dB
3500 MHz
27
dB
4000 MHz
Small Signal Gain
25
6000
MHz
42
dBm
50 MHz
44
dBm
100 MHz
42
dBm
200 MHz
43
dBm
500 MHz
44
dBm
850 MHz
44
dBm
1950 MHz
32.8
dBm
2500 MHz
39
dBm
3500 MHz
38
dBm
4000 MHz
Output Third Order Intercept Point
37
6000
MHz
29.5
dBm
50 MHz
33
dBm
100 MHz
32
dBm
200 MHz
32
dBm
500 MHz
28
dBm
850 MHz
26
dBm
1950 MHz
24
dBm
2500 MHz
24
dBm
3500 MHz
24
dBm
4000 MHz
Output Power at 1dB Compression
23
6000
MHz
Copyright © 2001-2016 RF-LINKS