Combustible material fireplace preparation – Empire Comfort Systems UNVENTED GAS LOG HEATER VFDR24LBN-1 User Manual

Page 10

Advertising
background image

Page 10

23099-1-0707

FOR MASONRY BUILT FIREPLACES

FREE OPENING AREA OF CHIMNEY DAMPER FOR

VENTING COMBUSTION PRODUCTS FROM DECORA-

TIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL

BURNING FIREPLACES

* Height is from hearth to top of chimney and the minimum

height is 6 feet.

** Chart shows minimum opening (sq. in.) for given height and

input rate.

• Turn off gas supply to fireplace or firebox.

• Have the fireplace floor and chimney professionally cleaned to

remove ashes, soot, creosote or other obstructions.

Have this cleaning performed annually after installation.

• Seal any fresh air vents or ash clean-out doors located on floor

or wall of fireplace. If not, drafting may cause pilot outage or

sooting. Use a heat-resistant sealant. Do not seal chimney flue

damper.

Install and operate the appliance as directed in this manual.

FOR FACTORY BUILT FIREPLACES

FREE OPENING AREA OF CHIMNEY DAMPER FOR

VENTING COMBUSTION PRODUCTS FROM DECORA-

TIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL

BURNING FIREPLACES

* Height is from hearth to top of chimney and the minimum

height is 10 feet.

** Chart shows minimum opening (sq. in.) for given height and

input rate.

Do not attach combustible material to the mantel of your fireplace.

This is a fire hazard.

Figure 7

No greeting card, stockings or ornamentation of any type should be

placed on or attached to the fireplace. This is a heating appliance.

The flow of heat can ignite combustibles.

Figure 8

Appliance Input Rate (BTU/hr)

20

30

40

Chimney

Height* (ft)

Minimum Opening** (sq. in.)

10

11.3

16.6

22.1

15

8.6

12.6

17.3

20

7.5

10.8

14.5

25

6.6

9.6

12.6

30

6.2

9.1

11.3

35

5.7

8.0

10.8

40

5.3

7.5

10.2

Appliance Input Rate (BTU/hr)

20

30

40

Chimney

Height* (ft)

Minimum Opening** (sq. in.)

6

17.6

25.7

33.8

8

16.5

23.7

31.2

10

15.1

21.7

28.7

15

14.1

19.9

26.1

20

12.9

18.5

23.7

30

12.2

16.9

21.6

COMBUSTIBLE MATERIAL

FIREPLACE PREPARATION