TOA Electronics ZM-9012 Assignable Volume Controller User Manual

TOA Electronics Audio accessories

Advertising
background image

ZM REMOTE CONTROLLER CONNECTION

INSTRUCTIONS (Supplementary)

When using the ZM Remote controller (ZM-9011, ZM-9012, ZM-9013, or ZM-9014 Remote

Control Panel), be sure to read the separate instruction manual in conjunction with this

supplementary manual.

1. CONNECTION

(Example of LINK A connections)

M-864D

Side view of the ZM

Remote controller

Notes

• Use the shielded Category 5 twisted pair LAN cable for connections between the ZM Remote

controller and the M-864D Digital Stereo Mixer (※ mark as shown above).

• Connect all cables as shown in the wiring diagram below.

Shield

Shielded wire

ZM 9011/9012/9013/9014

M-864D

Terminal

Cable (Color)

D+

White/Orange

D−

Orange

White/ Green

Green

Shield

24V+

White/Blue

White/Brown

24V–

Blue

Brown

URL: http://www.toa.jp/

133-05-00001-00

2. CABLE DISTANCE

Note

When 2 or more ZM Remote controllers are connected in a star topology, keep each cable length

within 10 m (33 ft) from the M-864D to a branch point.

(When connecting 16 ZM Remote controllers)

LINK A

LINK B

ZM Remote

controller (1)

(8)

Connection terminal

Connection terminal

(9)

(16)

Allowable total cable length

of wiring is 800 m (870 yd).

M-864D

Max. 10 m (33 ft) to

a branch point

Advertising