Maintenance

Replacement Filters

Kohler

Kohler

P/N 2405010–15 Micron

Briggs & Stratton

Briggs & Stratton
P/N 695327– 30 Micron

Change Hydraulic System
Filter

Service Interval: After the first 250 hours

Every 500 hours/Yearly
(whichever comes
first) thereafter
(Every 250 hours/Yearly if
using Mobil 1 15W50)

Note: Use only Exmark Part No. 103-2146.

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Carefully clean area around filter. It is important

that no dirt or contamination enter hydraulic
system.

3. Unscrew filter to remove and allow oil to drain

from reservoir.

Important: Before reinstalling new filter, fill
it with Exmark Premium Hydro oil and apply
a thin coat of oil on the surface of the rubber
seal.

Turn filter clockwise until rubber seal contacts the
filter adapter, then tighten the filter an additional
2/3 to 3/4 turn.

4. Fill reservoir as stated in Check Hydraulic Oil

Level section.

Exmark Premium Hydro Oil is recommended.
Refer to the chart for an acceptable alternative:

Hydro Oil

Change Interval

Exmark Premium Hydro
Oil (Preferred)

500 Hours

Mobil 1 15W50

250 Hours

5. Raise the rear of machine up and support with

jack stands (or equivalent support) just high
enough to allow drive wheels to turn freely.

CAUTION

Raising the mower for service or maintenance
relying solely on mechanical or hydraulic
jacks could be dangerous. The mechanical or
hydraulic jacks may not be enough support
or may malfunction allowing the unit to fall,
which could cause injury.

Do Not rely solely on mechanical or hydraulic
jacks for support. Use adequate jack stands
or equivalent support

6. Start engine and move throttle control ahead to

full throttle position. Move the speed control
levers to the full speed and run for several
minutes. Shut down machine and recheck oil
level.

Note: Do Not change hydraulic system oil (except
for what can be drained when changing filter), unless
it is felt the oil has been contaminated or been
extremely hot.
Changing oil unnecessarily could damage hydraulic
system by introducing contaminates into the system.

Check Wheel Hub Locknuts

Service Interval: After the first 100 hours

Every 500 hours thereafter

When tightening the lock nut on the wheel motor
tapered shaft:

Torque to 210-250 ft-lb (285-339 N-m).

Note: Do Not use antiseize on wheel hub.

Fuel Tank — Mounting
Hardware Specifications

Service Interval: As required

When installing the nuts on the fuel tank studs, fully
tighten the nyloc nut and back off 1/2 turn. This
allows for normal fuel tank expansion and contraction
with changes in temperature and fuel levels.

Thread Locking Adhesives

Thread locking adhesives such as “Loctite 242”
or “Fel-Pro, Pro-Lock Nut Type” are used on the
following fasteners: