Extron electronic Ultra Series User Manual
Page 133

4-23
CrossPoint / MAV Matrix Switchers • Programmer’s Guide
X5#
= Verbose mode
0 = clear/none (default for Telnet connection)
1 = verbose mode (default for RS-232/RS-422 connection)
2 = tagged responses for queries
3 = verbose mode and tagged for queries
N
If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set command does
(for example, the read matrix name command
E
CN
}
, returns Ipn•
X3)]
).
X5$
= Flow control
h
ardware, software, none (only the first letter required)
X5%
= Data pacing (in ms between bytes)
0000 (default) - 1000
X5^
= Time (in 10-ms increments) to wait for characters
10 (= 100 ms, default) - 32767
X5&
= Time (in 10-ms increments) to wait between characters 2 (= 20 ms, default) - 32767
X5*
= Port timeout interval (in 10-sec. increments)
1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)