ETM26E-03

8.3.2. Related registers for function of time update interrupts.

Address

Function

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

B

Timer Counter 0

128

64

32

16

8

4

2

1

C

Timer Counter 1

2048

1024

512

256

D

Extension Register

TEST

WADA

USEL

TE

FSEL1

FSEL0

TSEL1

TSEL0

E

Flag Register

{

{

UF

TF

AF

{

VLF

VDET

F

Control Register

CSEL1

CSEL0

UIE

TIE

AIE

{

{

RESET

∗1)

"o" indicates write-protected bits. A zero is always read from these bits.

∗2)

Bits marked with "•" are RAM bits that can contain any value and are read/write-accessible.

∗ Before entering settings for operations, we recommend writing a "0" to the TE and TIE bits to prevent hardware

interrupts from occurring inadvertently while entering settings.

∗ When the STOP bit or RESET bit value is "1" the time update interrupt function operates only partially.
(Operation continues if the source clock setting is 4096 Hz. Otherwise, operation is stopped.)

∗ When the fixed-cycle timer interrupt function is not being used, the fixed-cycle timer control register (Reg – B to C)
can be used as a RAM register. In such cases, stop the fixed-cycle timer function by writing "0" to the TE and TIE
bits.

1) TSEL0,1 bits (Timer Select 0, 1)

The combination of these two bits is used to set the countdown period (source clock) for the fixed-cycle timer
interrupt function (four settings can be made).

TSEL0,1

TSEL1

(bit 1)

TSEL0

(bit 0)

Source clock

Auto reset time

tRTN

Effects of

RESET bits

0 0

4096

Hz

/Once per 244.14

μs

122

μs

0 1

64

Hz /

Once per

15.625

ms

7.8125

ms

1

0

"Second" update /Once per second

7.8125

ms

Write/Read

1

1

"Minute" update /Once per minute

7.8125

ms

Does not operate
when the RESET
bit value is "1".

∗1) The /INT pin's auto reset time (tRTN) varies as shown above according to the source clock setting.
∗2) When the source clock has been set to "second update" or "minute update", the timing of both

countdown and interrupts is coordinated with the clock update timing.


2) Fixed-cycle Timer Control register (Reg - B

to C)

This register is used to set the default (preset) value for the counter. Any count value from 1

(001 h) to

4095

(FFFh) can be set. The counter counts down based on the source clock's period, and when the count value

changes from 001h to 000h, the TF bit value becomes "1".
The countdown that starts when the TE bit value changes from "0"

to "1" always begins from the preset value.

Be sure to write "0" to the TE bit before writing the preset value. If a value is written while TE =

"1" the first

subsequent event will not be generated correctly.

Address C

Timer Counter 1

Address B

Timer Counter 0

bit 7 bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

bit 7 bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

2048

1024

512

256

128

64 32 16 8 4 2 1


3) TE (Timer Enable) bit

This bit controls the start/stop setting for the fixed-cycle timer interrupt function.

TE

Data Description

0

Stops fixed-cycle timer interrupt function.

Write/Read

1

Starts fixed-cycle timer interrupt function.

The countdown that starts when the TE bit value changes from "0"

to "1" always begins from the

preset value.


4) TF (Timer Flag) bit

If set to "0" beforehand, this flag bit's value changes from "0" to 1" when a fixed-cycle timer interrupt event has
occurred. Once this flag bit's value is "1", its value is retained until a "0" is written to it.

TF

Data Description

0

The TF bit is cleared to zero to prepare for the next status detection

∗ Clearing this bit to zero does not enable the /INT low output status to be cleared (to Hi-Z).

Write

1

This bit is invalid after a "1" has been written to it.

0

Fixed-cycle timer interrupt events are not detected.

Read

1

Fixed-cycle timer interrupt events are detected.
(Result is retained until this bit is cleared to zero.)