Panamax MR5100 Power Management System User Manual

Model mr5100 reference guide, Back panel features

Advertising
background image

Specifications subject to change due to product upgrades and improvements.

*

Go to www.panamax.com for detailed noise filtering information.

Español - Para la versión en español de este documento, vaya a www.panamax.com/products

Français - Pour la version espagnole de ce document, allez à www.panamax.com/products

DIN-00017 - REV. C

OUTLET BANKS 1, 2 and 3

INDICATOR LEDS

POWER ON / OFF

ON / OFF, CONTROL FOR

DECORATIVE BLUE LIGHTS

(Blue lights can be illuminated when power is off)

SAFE POWER AND

VOLTAGE INDICATOR

UNSAFE VOLTAGE

INDICATOR

LINE FAULT

INDICATOR

FRONT PANEL

CONVENIENCE

OUTLET

USB CHARGER

8 ft. POWER

CORD,

NEMA 5-15

with Low Profile Plug

GROUND LUG

15 AMP CIR-

CUIT BREKAER

RESETTABLE

OUTLET BANK 3

(HIGH CURRENT)

OUTLET BANK 2

(SWITCHED)

OUTLET BANK 1

(ALWAYS ON)

LAN SURGE

PROTECTION

1 PAIR OF

RJ-45 IN/OUT

CONNECTORS

COAXIAL SURGE

PROTECTION

2 PAIRS

UNIVERSAL

IN/OUT

CONNECTORS

TELCO SURGE PROTECTION

1 PAIR OF RJ-11 IN/OUT CONNECTORS

Note to CATV Installers:

This reminder is provided to call attention to Article 820-40 of the NEC. That article provides

specific guidelines for proper grounding.It specifies that the cable ground shall be connected

to the grounding system of the building and as close to the point of entry as practical.

Front Panel Features

MR5100 Features and Specifications

Panamax LLC, 1690 Corporate Circle, Petaluma, CA 94954 • 707-283-5900 • 800-472-5555 • www.panamax.com

©2012 Panamax LLC, Panamax Logo is a US registered trademark of Panamax

Model MR5100 Reference Guide

AC PROTECTION

Protect or Disconnect Circuitry_________________________________________________Yes

Patented Power Management Circuit____________________________________________Yes

Overvoltage Shutoff____________________________________________________ 140V ±4

Undervoltage Shutoff___________________________________________________ 95V ±3V

Thermal Fusing___________________________________________________________Yes

Line Voltage___________________________________________________120VAC, 50/60HZ

Initial Clamping Level__________________________________________ 200V Peak, 141VRMS

Voltage Protection Rating (UL 1449 3rd Edition, 3,000A)____________________________400V

Protection Modes_________________________________________________ L-N, L-G, N-G

Maximum Current Rating_____________________________________________15A (1800W)

EMI/RFI Noise Filtration______________________________ Panamax Level 3 Noise Filtration*

Response Time__________________________________________________________< 1ns

Single Pulse Energy Dissipation_________________________________________1350 Joules

Peak Impulse Current___________________________________________________52,000 A

LAN PROTECTION

Clamping Level____________________________________________________ 62±6V @ 1 mA

Compatibility___________________________________________________10/100/1000bT

Wires Protected _______________________________________________________8-Wires

Connectors____________________________________________________________RJ-45

TEL PROTECTION

Fuseless/Auto-Resetting________________________________________________Yes

Clamping Level__________________________________________________________260V

Wires Protected _________________________________________________ 2 wire, 1 pair (4, 5)

Connectors_________________________________________________________RJ-11

UNIVERSAL COAX PROTECTION

HD 1080 i/p Ready_________________________________________________________Yes

Bidirectional__________________________________________________________Yes

Shielded____________________________________________________________Yes

Clamping Level___________________________________________________________75V

Frequency Range_________________________________________________OMHz - 2.2 GHz

Insertion Loss_________________________________________________________ <0.5 dB
Connections______________________________________________ Female “F”, Gold Plated

Key Features

Exclusive Automatic Voltage Monitoring (AVM)

Panamax’s patent pending power monitoring

circuitry constantly monitors the AC line voltage

for unsafe voltage conditions such as momentary

spikes, prolonged over-voltages and undervoltag-

es (brownouts). These unsafe conditions pose a

very dangerous threat to all electronic equipment

within the home. If the MR5100 senses an unsafe

power condition, it will automatically disconnect

power from your equipment to protect equip-

ment from damage. The front panel indicator will

also alert users to the power condition. Once the

voltage returns to a safe level, the MR5100 will

automatically reconnect the power to the outlets.

Protect or Disconnect™ Technologies

In the event of a catastrophic surge such as light-

ning, it completely disconnects AC power to con-

nected equipment.

Front Panel Outlet

MR5100 features a protected and noise filtered

convenience outlet located on the front panel.

Perfect for temporary gaming systems, por-

table electronics (such as music players or smart

phones), or other personal electronics.

Front Panel Decorative Lights

Blue decorative lights add an attractive look at feel

to your equipment rack or TV cabinet.

Antenna, Cable, Sat and LAN Signal protection

Coaxial protection circuits prevent damaging

surges from entering through signal paths and

have the smallest signal loss on the market - less

than 0.5 db of attenuation from 0Hz to 2.2GHz.

Our coaxial protection has been specifically

designed to virtually eliminate signal loss. The

clamping level of 75V will meet and exceed the

demands of both cable and satellite voltages

while minimizing exposure to damaging spikes

and surges. LAN protection allows for 10/100

base-T Ethernet equipment to integrate into an

audio/video system without the risk of upstream

surge damage from a gateway, switch, router or

other network device.

Eleven Protected and Filtered Power Outlets

(see specifications)

Ten Foot Power Cable with Straight Plug

NEMA 5-15P, fixed starin relief, unshielded,

straight plug.

TO GET STARTED
1.

Turn OFF the power to all equipment that will be plugged into the MR5100.

2.

Plug the MR5100 into the wall outlet then turn it ON.

3.

Verify that the LINE FAULT INDICATOR LED is NOT lit, indicating that the wall outlet is properly wired and

grounded. (If it is LIT call a licensed electrician to inspect and implement proper and safe wiring).

4.

Plug the equipment to be proteced into the MR5100 AC outlets and leave everything off until after the

LAN, TELEPHONE and COAX Lines are connected and then proceed to turn on your connected equipment.

IMPORTANT SAFETY POINTS

Panamax surge protectors and the connected equipment must be indoors, in a dry location and in the same
building. Although your Panamax protector is very durable, its internal components are not isolated from the
environment. Do not install any Panamax product near heat emitting appliances such as a radiator or heat register.
Do not install this product where excessive moisture is present; for example near a bath tub, sink, pool basement
floor, fish tank, etc. It is not uncommon for a building to be improperly grounded. In order to protect your equipment,
Panamax products must be plugged into a properly wired and grounded 3-wire outlet. Additionally, building wiring
and grounding must conform to applicable NEC (USA) or CEC (Canada) codes for the Panamax protection policy to
be valid. Do not use 2-blade adapters or any other “power strips” with this product. Use only Panamax extension
cord, or a UL / CSA recognized power cord.

Back Panel Features

BANK 1 ON

INDICATOR LIGHT

BANK 1 BANK 2 BANK 3

MR5100

CATV / SAT 1

UNIVERSAL COAX PROTECTION

CATV / SAT 2

TEL

OUT

IN

OUT

LAN

OUT

TEL

IN

LAN

IN

IN

OUT

BANK 3

HIGH CURRENT

DELAYED

OUTLETS

BANK 1

FILTERED / LIFT

ALWAYS ON

OUTLETS

BANK 2

FILTERED / LIFT

SWITCHED OUTLETS

BANK 1 ON

GROUND

LUG

15 AMP
CIRCUIT

BREAKER

MAIN POWER 120 VAC/15A

LAN PROTECTION

TEL PROTECTION

Advertising