Installation, Connecting the ductwork, Replacing the bottom trim – Electrolux E40PV100FS User Manual

Page 7

Advertising
background image

Installation

CONNECTING THE DUCTWORK

1 Use 8” round metal duct to connect the discharge collar on the hood to

the ductwork above.

2 Use duct tape to make all joints secure and air tight.

3 Remove the two temporary retaining screws from the lower flue and set

it in place on the hood.

4 Secure decorative flue to hood with two mounting screws (3.9 x 9.5mm).

pan head mounting screws.

LOWER

FLUE

RETAINING

SCREWS

8” ROUND

METAL

DUCT

MOUNTING

SCREWWS

(3.9 x 9.5 mm)

Figure 15

Figure 14

REPLACING THE BOTTOM TRIM

1 Remove the four (4) screws from the inside of the hood.
2 Remove the trim by pulling downward.
3 Slide the new trim upward into hood.
4 Replace the four screws inside hood.

Figure 16