background image

Description of the menu options

ELSA MicroLink Cable

R10

6

– If the device no longer responds and it is therefore impossible to log in, the

firmware automatically loads the previous firmware version and reboots the
device with it.

'manual': The third option allows you to set a period (Timeout firmsafe) beforehand
for testing the new firmware. The device will start with the new firmware and wait
for the preset period until the loaded firmware is manually activated and therefore
becomes permanently effective.

Other

The Other menu allows you to manage the following functions:

Boot-system

This option allows you to reboot the device.

Before executing the command all open connections will be released or closed. The
device must log back on with the network operator after rebooting.

Factory-default-
system

This option resets all the settings that have been entered. The device is reset to the
factory settings.

For security reasons, the system prompts you to enter the configuration protection
password in order to ensure that you have not mistakenly selected this command instead
of the

Boot-system

command. If no password has been assigned, you must press

Enter a second time.

Upload-system

This option starts a firmware upload (refer to chapter 'How to load new software').

The flash ROM technology permits flexible and service-friendly handling of the system
software by allowing different firmware versions to be read in. It also allows devices to
be retrofitted with all future options.

/Other

Various functions

Boot-system

Boots the device

Factory-default-
system

Resets to factory settings

Upload-system

Loads new firmware

Advertising