If you are using one or more MDA, Hercules, or CGA

display adapter cards, you may need to change the setting of

jumper J4 inside your computer. The jumper tells the

computer whether you are using a color or monochrome

monitor. (Jumper J4 is set to the color monitor position at

the factory.) If the jumper is set incorrectly, you see one of
the following messages:

401

CRT ERROR

501

CRT ERROR

If you are using two different types of video cards, set jumper

J4 to the primary monitor type. You may also need to

change this jumper later if you change the type of monitor

you are using. See “Changing the Jumper Settings” in

Chapter 5 for instructions.

Password Problems

If you set a power-on password using the Setup program, you
must turn on your computer and enter this password before you
can use the system. When you turn on the computer, the screen

displays a key prompt

). If you do not enter the correct

password, you see an X on the screen to indicate it is incorrect.

The computer gives you a second and third chance to enter it

correctly.

If after three tries you have not entered the correct password,
the computer locks up and does not respond to your keyboard
entries.

Note

If you enabled network server mode when you set a password,

you may not see the key prompt. For more information, see

“Using Your Computer as a Network Server" in Chapter 4.

D-8

Troubleshooting

Advertising