Rx - 8581 sa – Epson RX-8581JE User Manual

Page 31

Advertising
background image

RX

-

8581

SA

/

JE

/

NB

Page - 28

MQ372-02

11. Application notes

11.1. Notes on handling

This module uses a C-MOS IC to realize low power consumption. Carefully note the following cautions when
handling.

(1) Static electricity

While this module has built-in circuitry designed to protect it against electrostatic discharge, the chip could still be
damaged by a large discharge of static electricity. Containers used for packing and transport should be constructed of
conductive materials. In addition, only soldering irons, measurement circuits, and other such devices which do not leak
high voltage should be used with this module, which should also be grounded when such devices are being used.

(2) Noise

If a signal with excessive external noise is applied to the power supply or input pins, the device may malfunction or "latch
up." In order to ensure stable operation, connect a filter capacitor (preferably ceramic) of greater that 0.1F as close as
possible to the power supply pins (between VDD and GNDs). Also, avoid placing any device that generates high level of
electronic noise near this module.
* Do not connect signal lines to the shaded area in the figure shown in Fig. 1 and, if possible, embed this area in a GND
land.

(3) Voltage levels of input pins

When the input pins are at the mid-level, this will cause increased current consumption and a reduced noise margin, and
can impair the functioning of the device. Therefore, try as much as possible to apply the voltage level close to VDD or
GND.

(4) Handling of unused pins

Since the input impedance of the input pins is extremely high, operating the device with these pins in the open circuit
state can lead to unstable voltage level and malfunctions due to noise. Therefore, pull-up or pull-down resistors should be
provided for all unused input pins.

11.2. Notes on packaging

(1) Soldering heat resistance.

If the temperature within the package exceeds +260

°

C, the characteristics of the crystal oscillator will be degraded and it

may be damaged. The reflow conditions within our reflow profile is recommended. Therefore, always check the mounting
temperature and time before mounting this device. Also, check again if the mounting conditions are later changed.
* See Fig. 2 profile for our evaluation of Soldering heat resistance for reference.

(2) Mounting equipment

While this module can be used with general-purpose mounting equipment, the internal crystal oscillator may be damaged
in some circumstances, depending on the equipment and conditions. Therefore, be sure to check this. In addition, if the
mounting conditions are later changed, the same check should be performed again.

(3) Ultrasonic cleaning

Depending on the usage conditions, there is a possibility that the crystal oscillator will be damaged by resonance during
ultrasonic cleaning. Since the conditions under which ultrasonic cleaning is carried out (the type of cleaner, power level,
time, state of the inside of the cleaning vessel, etc.) vary widely, this device is not warranted against damage during
ultrasonic cleaning.

(4) Mounting orientation

This device can be damaged if it is mounted in the wrong orientation. Always confirm the orientation of the device before
mounting.

(5) Leakage between pins

Leakage between pins may occur if the power is turned on while the device has condensation or dirt on it. Make sure the
device is dry and clean before supplying power to it.


Fig. 1 : Example GND Pattern


Fig. 2 : Reference profile for our evaluation of Soldering heat resistance.

RX - 8581 SA

( SOP-14pin )

RX - 8581 JE

( VSOJ-20pin )

RX - 8581 NB

( SON-22pin )





























+1

+5

°

C / s

100 s

Pre-heating area

1

5

°

C / s

time [ s ]

Temperature [

°

C ]

+170

°

C +220

°

C

+260

°

C

Max.

+1

+5

°

C / s

35 s

Stable Melting area

Advertising