4

Figure 4. The location of the acoustic axis.

Figure 5. Symmetrical layout and keeping the acoustic axis clear

from obstructions minimizes reflection surfaces and maintains

accurate localisation because reflections are symmetrical.

Monitor

Mounting Position

Treble

Tilt

Bass

Tilt

Bass

Roll-Off

Desktop

Flat anechoic

response

None

None

None

None

Free standing in

a damped room

None

-2 dB

None

None

Free standing in

a reverberant room

None

-4 dB

None

None

Near field on

a reflective surface

None

-2 dB

None

-4 dB

In a corner

None

-4 dB

-4 dB

None

Table 1. Suggested Tone Control settings for some typical monitor

placement positions.

Stand-Alone Functionality

Bass Roll-Off Control

The Bass Roll-Off setting reduces bass level for spaces with

strong low frequency reverberation. It reduces output near the

low cut-off. Attenuation can be selected by combining settings

on one or more switches.

Desktop reflection compensation

The desktop control reduces frequencies near 160 Hz by 4 dB.

This compensates the boost when the monitor is placed on a

meter bridge or table.

Bass Tilt Control

The Bass Tilt control offers three attenuation levels for the

response below 800 Hz. This control is used when monitors are

placed near wall or room corner. Attenuation can be selected by

combining settings on one or more switches.

Treble Tilt Control

The Treble Tilt control adjusts the high frequencies above 5 kHz.

It corrects bright or dull sound and compensates high frequency

loss when a monitor is placed behind a screen.

LED Disable

This switch turns off the front panel LED light.

ISS

This switch activates and deactivates the ISS power saving

function when the 8361 is used in a Stand Alone mode. The

default time for going to power save mode is 60 minutes, but

this can be adjusted in the GLM software.

Digital

The Digital switch selects the digital audio signals A and B carried

in one AES/EBU cable. Turning on both switches reproduces the

sum of the signals. When both are selected, a 6 dB attenuation

is applied to avoid an overload.

Level

The Level switches reduce the monitor output in 10 dB steps

(-10 dB, -20 dB and both switches -30 dB). The switches

combine with the rotary level adjustment. The total adjustment

range is 42 dB. GLM software enables wider level adjustment.

Stored

The Stored switch selects between the controls on the monitor

back panel (OFF position) or applying the settings stored in the

monitor using the GLM software (ON position).

Operating Environment

This product is designed for indoor use only. The permissible

ambient temperature is 15-35 degrees Celsius (50-95°F) and

relative humidity 20% to 80% (non-condensing). To prevent

condensation after the product has been in a cool environment,

wait at least one hour before opening the packaging and

connecting the mains power.

Cooling of the 8361A must be ensured. The minimum

h1 = 237 mm (9 5/16 in)

h2 = 169 mm (6 10/16 in)

ACOUSTIC
AXIS

h1

ACOUSTIC
AXIS

h2