Glass & stainless canopy hood – Electrolux RH42PC60GS User Manual

Page 2

Advertising
background image

Glass & Stainless Canopy Hood

RH42PC60G S

High standards of quality at Electrolux Major Appliances mean we are

constantly working to improve our products. We reserve the right to change

specifications or discontinue models without notice.

USA

•

250 Bobby Jones Expressway

•

Augusta, GA 30907

•

1-877-4electrolux (1-877-435-3287)

•

electroluxappliances.com

CANADA

•

5855 Terry Fox Way

•

Mississauga, ON L5V 3E4

•

1-800-265-8352

•

electroluxappliances.ca

RH42PC60G 02/08

© 2008 Electrolux Major Appliances, NA

Printed in the U.S.A.

42" Glass & Stainless Canopy Island Hood Specifications

•

Product Weight – 87 Lbs.

•

Island / Peninsula Installation

•

Ventilation is convertible to be either ducted outside, or recirculated
inside requiring no ducting.

•

Sones Rating – 9.0

•

Voltage Rating – 120V / 60 Hz / 15 Amps

•

Connected Load (kW Rating) @ 120 Volts = 0.516 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)

•

Amps @ 120 Volts = 4.16 Amps

•

Always consult local and /or national electric codes. Check local
building codes for installation requirements, as they may vary per locale.

•

Minimum installation height allowed from bottom of hood to cooking
surface is 24" - 30" for electric and 30" for gas. (NOT more than 36"
recommended.)

•

To prepare mounting surface, adequate structure and support must be
provided, capable of supporting 150 lbs.

Ducted Option Specifications

•

For outside ventilation only.

•

Exhaust Duct Required – 8" round

•

For most efficient airflow exhaust, use a straight run or as few elbows
as possible.

•

Use metallic flex ducting only to connect rigid duct directly to transitions
(if allowed by code).

•

Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.

•

Cold weather installations should have additional backdraft damper
installed.

•

Refer to web for detailed duct preparation installation instructions.

Ductless (Recirculated) Option Specifications

•

If ducting to outside is not an option, vent hood can be converted to
ductless with use of optional Duct-Free Kit (RHDFP60GS).

•

Refer to web for detailed convertible ventilation installation instructions.

Pre-Installation Calculations

•

Select hood preference height (P) that is comfortable for user
(24" - 30" minimum allowed, NOT more than 36" recommended).

•

Calculate hood height (H) for installation (H = K-C-P).

•

Confirm that (H) is within minimum to maximum range for hood.
If not, adjust installation.

•

Calculate chimney structure height (S). Use formulas, check
dimensions of hood. Save calculation for use later in installation.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at electroluxappliances.com for detailed instructions.

Optional Accessories

•

Duct-Free Kit – (RHDFP60GS).

Top

Controls

Wiring box

Air outlet -
7

7

/

8

" diam.

Dimensions
from base of
hood to ceiling,
and include
clearance
required for
installation.

41

7

/

8

"

25

3

/

16

"

2

11

/

16

"

12

1

/

8

"

13

3

/

16

"

35"
min.

57"

max.

28"

( min.

height

with one

cover)

K = Kitchen height
C = Counter height
P = Preferred height

of hood bottom
above counter
(24"- 30"
allowed, NOT
more than 36"
recommended)

A = Canopy height
H = Hood height for

installation

H = K-C-P
S = Chimney

structure height
for installation

S = H-A

PRE-INSTALLATION CALCULATIONS

S H

A

K

P

C

Counter Height

36" standard

Advertising