Clearances to combustibles - freestanding, Clearances to combustibles - fireplace insert, Installation – Enviro EF2 User Manual

Page 13

Advertising
background image

Installation

C

LEARANCES

TO

C

OMBUSTIBLES

- F

REESTANDING

:

When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non-

combustible hearth pad must be under the unit. The pad must extend at least the width of the appliance

[22” (558 mm)] and at least the depth of the appliance plus 6” (153 mm) in front of the appliance [29

3⁄4” (756 mm)].

Side wall to unit

- 6 inches

(15 cm)

Back wall to unit

- 1 inches

(2.5 cm)

Corner to unit

- 1 inches

(2.5 cm)

Door front to edge of floor protection

- 6 inches

(15 cm)

30"

(76 cm)

48"

(122 cm)

36"

(91cm)

��

���� ���

��

��� ���

��

��� ���

��

���� ���

���� ����

��

��

��

����

���

���

����� ����������

Figure 8: EF2 Freestanding Clearance to Combustibles.

Minimum Alcove width

- 36 inches (91 cm)

Minimum Alcove height

- 48 inches (122 cm)

Minimum Alcove depth

- 30 inches (76 cm)

Figure 9: EF2 Freestanding Minimum Alcove Size.

C

LEARANCES

TO

C

OMBUSTIBLES

- F

IREPLACE

I

NSERT

:

10" (25.4 cm) Mantel

8"

(20.3 cm)

8"

(20.3 cm)

S

id

e

W

al

l

Floor Protection; Minimum 6" (15 cm) in front of door

Figure 10: EF2 Fireplace Insert Clearance to Combustibles.

Refer to Figure 10.
Side wall to unit

- 8 inches

(20.3 cm)

Mantel projection

- 10 inches

(25.4 cm)

Mantel to top of unit - 8 inches

(20.3 cm)

Top facing to unit

- 8 inches

(20.3 cm)

Side facing to unit

- 6 inches

(15.2 cm)

Floor protection

- 6 inches

(15.2 cm)

on either side and to the front must

be protected by non-combustible material.

These dimensions are minimum clearances but it is

recommended that you ensure sufficient room for

servicing, routine cleaning and maintenance.

13

Advertising
This manual is related to the following products: