PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly

against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.

Note: The thermostat mode can be changed during normal operation.

MANUAL MODE:

All control of circuit board function is adjusted at the circuit board.

To START: Press the ON / OFF button. The stove will turn on. The

system light will flash. The Auger Light will flash with each pulse of

the auger (the Auger Feed Rate is pre-programmed during start-up).

The Heat Level Indicator will show the Heat Level that the stove will

run at after start-up.

If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to

be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see

“O

PERATING

I

NSTRUCTIONS

; C

ONTROL

B

OARD

F

UNCTIONS

”).

To OPERATE: When a fire has been established, the System Light will turn solid (after approximately 10

- 15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting. The Heat

Level button can now be pressed at this time to change the desired Heat Level Output setting.

The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting

of the heat level output indicator. The convection blower can be turned OFF by depressing the convection

blower control button. For the best efficiency and to prevent cycling, the convection blower should be

left on at all times.

When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different

quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the

low setting is too hot for the room (see “O

PERATING

I

NSTRUCTIONS

; C

ONTROL

B

OARD

F

UNCTIONS

”).

Figure 3: Thermostat Switch in

MANUAL poition.

Figure 4: Thermostat Switch in

HIGH/LOW poition.

HIGH/LOW MODE: (Requires a thermostat)

INITIAL START-UP: See manual mode above.

OPERATION: When the thermostat calls for heat (contacts are

closed) the stove settings are adjustable as per Manual Mode. When

the thermostat contacts open, the HEAT LEVEL and Fans will drop

down to the LOW setting until the thermostat contacts close again.

*The LOW heat setting can be adjusted for different fuel qualities

(see “O

PERATING

I

NSTRUCTIONS

- C

ONTROL

B

OARD

F

UNCTIONS

”). The stove will

come back to the previous HEAT LEVEL setting when the thermostat contacts close again.

AUTO/OFF MODE: (Requires a thermostat)