Troubleshooting procedures, Squelch checks – Ericsson LBI-38505A User Manual

Page 10

Advertising
background image

TROUBLESHOOTING PROCEDURES

SQUELCHED

UNSQUELCHED

NOISE SQ OUTPUT

U605-2

0.2 VDC

9.9V

CAS

U605-1

0.1 VDC

9.9V

RX MUTE

U605-14

0.2 VDC

9.9V

RUS

U605-13

0.2 VDC

4.9V

SQ DISABLE SW. INPUT

U606-1

0.2 VDC

9.9V

AUDIO GATE SW. CONTROL

U606-11

0.2 VDC

9.9V

If External Decoder is used (CG, DCG, Type 99, etc.), RX Mute will remain low (regardless of noise squelch output), until proper

response is decoded. RX Mute = Noise Sq Output

•

Decoder Output.

In above cases, Sq Disable is assumed high (9.9V). If Sq Disable is grounded, U606-10 = 0.2 Vdc, U606-11 = 9.9 Vdc and Unit

is unsquelched for all conditions.

SQUELCH CHECKS

SYMPTOM

PROCEDURE

IMPROPER SQUELCH OPERATION

•

Check voltages on Schematic Diagram.

•

Make gain and waveform checks with noise.

•

Make gain and waveform checks with 6 kHz signal.

•

Check discrete components in the squelch circuit.

•

Replace IC circuit U603.

LOW OR DISTORTED AUDIO

•

Check voltages on Schematic Diagram.

•

Make gain and waveform checks.

•

Check receiver alignment and FM -DET output.

•

Check Q601, Q602, Q605 and other discrete components.

SYMPTOM CHECKS Con’t.

LBI-38505

LBI-38505

9