Eaton Electrical Cutler-Hammer CA03310002E User Manual

Page 7

Advertising
background image

September 2003

CA03310002E

For more information visit: www.cutler-hammer.eaton.com

7

NEMA Contactors & Starters
IT.
Electro-Mechanical

Starters — Full Voltage, Non-reversing and Reversing

Contents

Description

Page

Product Family Overview

Product Description . . . . . . 2

Standards and

Certifications . . . . . . . . . . 2

Catalog Number

Selection . . . . . . . . . . . . . 3

Starters — Non-reversing

and Reversing

Product Description . . . . . . 7

Features . . . . . . . . . . . . . . . 7

Product Selection . . . . . . . . 8

Technical Data . . . . . . . . . . . . . 10

Accessories . . . . . . . . . . . . . . . 13

Auxiliary Contacts . . . . . . . 15

Dimensions . . . . . . . . . . . . . . . 22

Product Description

The Cutler-Hammer Intelligent Tech-
nologies (IT.) Electro-Mechanical
Starter by Eaton Corporation consists
of an IT. Electro-Mechanical Contact
Block or Contactor and IT. Electro-
Mechanical Solid-State Overload Relay
as a Full Voltage Non-reversing (FVNR)
or Full Voltage Reversing (FVR) device.
Size 00 to Size 5 Starters are factory or
field assembled.

Features

■

24V DC control power — safe, reliable
global standard

■

Unique Pulse Width Modulated
(PWM) coil controller minimizes coil
power consumption

■

Microprocessor based control

■

Phase loss and current unbalance
protection, user selectable

■

Standard selectable Trip Class 10, 20
(factory default) or 30 — no individ-
ual part numbers — no program-
ming software

■

Ambient compensated overload

■

Motor temperature and power-up
protection with thermal memory

■

Front and side mounted Auxiliary
Contacts: 1NO, 1NC, 2NO, 2NC,
1NO/1NC and logic level (1NO/1NC)

■

Easily accessible mounting feet for
panel mounting

■

LED status indication — trip, trip
class, motor thermal state, reset,
overload state

■

Unique “Alarm without Trip” option
for critical must run applications

■

Lockable overload cover protects
against unauthorized adjustment
and reset functions

■

No control wiring needed between
contactor and overload relay —
eliminates seal in auxiliary contacts

■

Minimal heat — no full voltage coils

■

-40° to 149°F (-40° – 65°C) operating
temperature

■

Wide 3.2:1 current adjustment range

■

Exclusive internal 24-bit floating
point math calculations with RMS
calibrated current measurement

■

Meets or exceeds global standards
for EMC (Electromagnetic compati-
bility) immunity and emissions

■

IP20 Finger Protection

■

Motor running thermal utilization
indication

■

Manual, Automatic or Remote Reset

■

Easy field assembly of control
wiring — plug and unplug lockable
control connector

■

DIN rail mountable, Size 00 – 2

■

Communication Interface with
Starter Network Adapter Product
(SNAP)

■

2- or 3-wire control

■

Solid-state alarm output indication

■

Optional mounting plates with
“Ease of Installation” slotted hole
design

■

Type 2 Coordination

■

Conformal coated printed circuit
boards for resistance to harsh
environments

Reversing Starters

■

Includes Reversing Power Wiring
and bus bars

■

Mounting plates for Size 00 – 4

■

Built-in electronic interlock for FVR
units

■

Unique overload board energizes
both forward and reverse starters —
one control point for wiring

NEMA Full Voltage
Non-reversing Starter, Size 0

NEMA Full Voltage Reversing
Starter, Size 0

Advertising