Operating Instructions

C

ONTROL

B

OARD

F

UNCTIONS

:

1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim

button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the feed

rate to four (4) seconds ON time per Auger pulse. This is done only on LOW to allow the burning of

poor quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On

time to two (2) second. This setting is for high-grade fuel only. Push the button until just the number

1 light is on, this is for a three (3) second on time (standard setting).

2. AUGER PULSE LIGHT: This light will flash in conjunction with the auger.

MANUAL FEED

ON/OFF

HEAT LEVEL

2

1

7

5

4

3

3. MANUAL AUGER FEED: If the unit runs out of fuel, this

button can be used to “prime the auger system”. This button

will turn off after 60 seconds and then must be released and

pressed again.

4. SYSTEM LIGHT: Responsible for signaling the state of the

control board. When the light is flashing during start-up, the

stove is in an automatic start mode. When the light is solid,

the Heat Level Setting can be altered.

5. ON/OFF BUTTON: Used to turn the unit ON and OFF.
6. HEAT OUTPUT INDICATOR: Shows the present heat

output setting.

7. HEAT LEVEL ADJUSTMENT: When pressed, the heat

output setting of the unit will change from low to high.

Notes:
• The convection blower speed will vary automatically with the

feed rate.

• Due to varying fuel qualities this pellet stove may not operate

on lower Heat Level settings. If your unit goes out when on a

low setting move the heat level up to a higher setting.

• The lowest and highest heat levels on this pellet stove are

Figure 3: Circuit Board Control Panel Decal.

Auger Trim

Auger Trim

Auger Trim

2 Seconds

"ON"

3 Seconds

"ON"

Factory Setting

4 Seconds

"ON"

1

1

1

4

5

Figure 4: Auger trim and heat level indicator.

used for adjusting and accommodating

for different pellet sizes and the varying

energy produced by the fuels. The size

of the pellets will change the volume of

fuel being fed.

• The unit should be run at a setting

where the least amount of cleaning of

the burn pot is needed.