4.

Start the hold-down screws into the hold-down brackets.

5.

Center the cooktop in the opening and, using a wood block

between the screw and the countertop, moderately tighten

the screws to secure cooktop.

IMPORTANT:

Do not tighten screws directly against the

countertop.

Make Electrical Connection

This cooktop is manufactured with a frame-connected green or

bare ground wire. Connect the cooktop cable to the junction box

through the UL Listed or CSA Approved conduit connector.

Electrical Connection Options

If Your Home Has: And You Will Be

Connecting to:

Go to Section:

4-wire direct

A fused disconnect

or circuit breaker

box

4-Wire Cable

from Home Power

Supply

(12.7 cm)

5"

3-wire direct

A fused disconnect

or circuit breaker

box

3-Wire Cable

from Home Power

Supply - U.S.A.

Only

(8.9 cm)

3

¹⁄₂

"

4-Wire Cable from Home Power Supply

IMPORTANT:

Use the 4-wire cable from home power supply in

the U.S.A. where local codes do not allow grounding through

neutral, New Branch circuit installations (1996 NEC), mobile

homes and recreational vehicles, New constructions, and in

Canada.

1.

Disconnect power.

2.

Remove junction box cover, if present.

3.

Connect the 2 red wires (B) together using a UL listed wire

connector.

4.

Connect the green (or bare) ground wire (C) from the cooktop

cable to the green (or bare) ground wire (in the junction box)

using the UL listed wire connectors.

5.

Put a UL listed wire connector on the end of the white

wire (F).

NOTE:

Do not connect the green (or bare) ground wire to the

neutral (white) wire in the junction box.

6.

Connect the 2 black wire (H) together using a UL listed wire

connector.

7.

Reinstall junction box cover.

A

B

C

E

D

A. Countertop
B. Wood block
C. Hold-down screw
D. Hold-down bracket
E. Burner box

WARNING

Electrical Shock Hazard

Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,

fire, or electrical shock.

H

G

E

I

A

D

B

C

F

A. Cable from home power supply
B. Red wires
C. Green (or bare) ground wires
D. 3-wire cable from cooktop
E. Junction box

F. White wire (from home power

supply)

G. UL listed wire connector
H. Black wires
I. UL listed or CSA approved

conduit connector with wire

bushing