Enerco HSIR30LPT User Manual

Page 16

Advertising
background image

16

Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

SPECIFICATIONS

IR10 LP

IR20LPT

IR30LPT

BTU (Available)

10,000

20,000

30,000

Type of Gas

LP-Gas Only

LP-Gas Only

LP-Gas Only

Ignition

Piezo

Battery ignitor (1-AA) Battery ignitor (1-AA)

Pressure Regulator Setting

10 Inches of Water 10 Inches of Water 10 Inches of Water

Inlet Gas Pressure (Maximum)

14 Inches of Water 14 Incheds of Water 14 Inches of Water

Inlet Gas Pressure (Minimum)

11 Inches of Water 11 Inches of Water 11 Inches of Water

Electrical Rating /Blower

120V, 60Hz , 1

120V, 60Hz , 1

Burners / Orifice nozzles

2

3

4

Thermostatic Control

No

Yes

Yes

Clearances: inches (mm)

Top

36” (915cm)

36” (915cm)

36” (915cm)

Sides

6” (152cm)

10.5” (267cm)

10.5” (267cm)

Floor (min. to top of carpet)

2” (51cm)

2” (51cm)

2” (51cm)

Fabric / flammable objects

36” (915cm)

36” (915cm)

36” (915cm)

BF6LP

BF10LP

BF20LPT

BF30LPT

BTU (Available)

6,000

10,000

20,000

30,000

Type of Gas

LP-Gas Only

LP-Gas Only

LP-Gas Only

Ignition

Piezo

Battery ignitor (1-AA) Battery ignitor (1-AA)

Pressure Regulator Setting

10 Inches of Water 10 Inches of Water 10 Inches of Water

Inlet Gas Pressure (Maximum)

14 Inches of Water 14 Inches of Water 14 Inches of Water

Inlet Gas Pressure (Minimum)

11 Inches of Water 11 Inches of Water 11 Inches of Water

Electrical Rating /Blower

120V, 60Hz , 1

120V, 60Hz , 1

Burners / Orifice nozzles

1

1

1

Thermostatic Control

No

Yes

Yes

Clearances: inches (mm)

Top

36” (915cm)

36” (915cm)

36” (915cm)

Sides

6” (152cm)

10.5” (267cm)

10.5” (267cm)

Floor (min. to top of carpet)

2” (51cm)

2” (51cm)

2” (51cm)

Fabric / flammable objects

36” (915cm)

36” (915cm)

36” (915cm)

Advertising