Model 1200 brick placement, Installation – Enviro KODIAK 1200 User Manual

Page 33

Advertising
background image

Installation

M

ODEL

1200 B

RICK

P

LACEMENT

:

COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.

1. Place the three (3) full size bricks along each side of the firebox and one (1) full size brick on either

side of the back of the firebox.

2. To place the floor bricks, lay the two (2) partial bricks along the back of the floor. Then on the left, lay

two (2) full size bricks and on the right, lay a full size brick in the center and the half brick in the front

(for the ash dump). The spaces between the bricks will soon fill with ashes.

When replacing bricks, use only pumas type fire bricks.
TOTAL BRICKS:
11 - Full size bricks 9” long x 4.5” wide x 1.25” thick

(22.9 cm long x 11.4 cm wide x 3.2 cm thick)

2 - Partial bricks 9” long x 3” wide x 1.25” thick

(22.9 cm long x 7.6 cm wide 3.2 cm thick)

1 - Half brick

4.5 “ long x 4.5” wide x 1.25” thick

(11.43 cm long x 11.43 cm wide x 3.175 cm thick)

���

���

� ��

���

��

��

���

��

���

� ��

��

���

��

Figure 40: Brick Placement for 1200 shown with Secondary Air Channel and Tubes.

33

Advertising
This manual is related to the following products: