Maintenance

DANGER

Jump starting a weak battery that is cracked,
frozen, has low electrolyte level, or an
open/shorted battery cell, can cause an
explosion resulting in serious personal injury.

Do Not jump start a weak battery if these
conditions exist.

2. Make sure the booster is a good and fully charged

lead acid battery at 12.6 volts or greater. Use
properly sized jumper cables (4 to 6 AWG) with
short lengths to reduce voltage drop between
systems. Make sure the cables are color coded or
labeled for the correct polarity.

CAUTION

Connecting the jumper cables incorrectly
(wrong polarity) can immediately damage the
electrical system.

Be certain of battery terminal polarity and
jumper cable polarity when hooking up
batteries.

Note: The following instructions are adapted
from the SAE J1494 Rev. Dec. 2001 – Battery
Booster Cables – Surface Vehicle Recommended
Practice (SAE – Society of Automotive
Engineers).

WARNING

Batteries contain acid and produce explosive
gases.

Shield the eyes and face from the batteries
at all times.

Do Not lean over the batteries.

Note: Be sure the vent caps are tight and level.
Place a damp cloth, if available, over any vent
caps on both batteries. Be sure the vehicles do
not touch and that both electrical systems are
off and at the same rated system voltage. These
instructions are for negative ground systems only.

3. Connect the positive (+) cable to the positive (+)

terminal of the discharged battery that is wired to
the starter or solenoid as shown in Figure 19.

Figure 19

1.

Positive (+) cable on discharged battery

2.

Positive (+) cable on booster battery

3.

Negative (–) cable on the booster battery

4.

Negative (–) cable on the engine block

5.

Booster battery

6.

Discharged battery

7.

Engine block

4. Connect the other end of the positive cable to the

positive terminal of the booster battery.

5. Connect the black negative (–) cable to the other

terminal (negative) of the booster battery.

6. MAKE THE FINAL CONNECTION ON

THE ENGINE BLOCK OF THE STALLED
VEHICLE (NOT TO THE NEGATIVE POST)
AWAY FROM THE BATTERY. STAND BACK.

7. Start the vehicle and remove the cables in the

reverse order of connection (the engine block
(black) connection is the first to disconnect).

Check Mower Blades

Service Interval: Before each use or daily

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Lift deck and secure in raised position as stated in

the Clean Grass Build-Up Under Deck section.

3. Inspect blades and sharpen or replace as required.

4. Reinstall the blades (if they were removed) in the

following order:

A. Install the splined bushing through the blade

with the bushing flange on bottom (grass)
side of blade.

29