DATA LINK TO GTI UNITS

32

DATA LINK TO GTI UNITS

The GTI Configurator must be able to communicate with one GTI unit in a system. If two or more GTI Configurator are
permitted to access a specific system, only one can have access at a time. Any changes made to the user database in this GTI
unit will also be made in the remaining GTI units via the PCM/Data bus. The GTI Configurator can communicate with a GTI
unit in a system in one or more of the following three ways (listed in order of increasing difficulty):

•

Local RS-232 Link - Requires the following:

•

Available serial COM port on GTI Configurator (PC)

•

Interconnect cable (PC to GTI) no more than 50 feet long

•

Remote RS-232 Link with Internal GTI Modem - Requires the following:

•

Available serial COM port on GTI Configurator (PC)

•

Interconnect cable (PC to modem)

•

Hayes (or Hayes compatible) modem (1200 bps)

•

Interconnect cable (modem to telephone line)

•

Available telephone line (GTI Configurator (PC) end)

•

Remote RS-232 Link with External GTI Modem - Requires the following:

•

Available serial COM port on GTI Configurator (PC)

•

Interconnect cable (PC to modem)

•

Hayes (or Hayes compatible) modem (recommend 9600 bps)

•

Interconnect cable (modem to telephone line)

•

Available telephone line (GTI Configurator (PC) end)

•

Available telephone line (GTI unit end - in addition to the normal telephone line going to the GTI unit for
interconnect calls)

•

Interconnect cable (telephone line to external GTI modem)

•

External GTI modem (recommend 9600 bps - must match modem at PC end)

•

Interconnect cable (external GTI modem to GTI unit)

LOCAL DATA LINK

If the distance between the GTI unit and GTI Configurator is short, a cable (no longer than 50 feet) can be connected from the
RS-232 port on the rear panel of the GTI unit directly to a serial COM port on the GTI Configurator. This connection can be
used when the GTI Configurator is located with the system of GTI units or in a nearby office. To set up the local RS-232 link,
use the following procedure:

1.

If the COM port on the GTI Configurator is a male DB-9 connector, connect it to the RS-232 port on the GTI unit,
as shown in Figure 23. If the COM port on the GTI Configurator is a male DB-25 connector, connect it to the RS-
232 port on the GTI unit, as shown in Figure 24. A 10-foot RS-232 cable with male and female DB-9 connectors is
supplied with the ELI option.