48
 
There are 5 motion trigger areas, which can be distinguished by 5 different colors. 
Check Enable checkbox to enable event action. 
For each of them, you can set the event action to be activated. Event action can be 
set in “Event” section. 
Moreover, you can set the Sensitivity level for motion triggered by selecting from 
1 (low), 2, 3, 4, 5, 6, 7, 8, 9 to 10 (high). 
 
4.7.3 Alarm
 
Alarm Output Setting 
 
Contact Type: Normal Close, Normal Open 
Duration Time: Select duration time of alarm output from 5 sec, 10 sec, 20 sec, 30 
sec, 60 sec, 2 min, 3 min and 5 min. 
 
Press Apply to apply the setting changes or Reset to reset without saving the 
change. 
 
Pre/Post Alarm Setting 
This function is used to check what happened immediately before and after a 
trigger, e.g. 5 seconds before or after a motion has been detected. 
Pre-Alarm Buffer: Image saved internally in the server from the time immediately