Specifications and Characteristic Data
Environmental Specification
Operating temperature and humidity ranges may vary depending upon the
mass storage devices installed. High humidity levels can cause improper
operation of disk drives. Low humidity levels can aggravate static electricity
problems and cause excessive wear of the disk surface.
System Processing Unit with a Hard Disk
Typical power consumption
30 W to 40 W (before installing any customer-specific accessories)
Acoustic noise emission
less than 40 dB in the workplace under normal conditions as
defined by DIN 45635 T.19 and ISO 7779
Operating temperature
+5°C to +40°C
(+40°F to 104° F)
Recommended operating temperature
+15°C to +40°C
(+59°F to +104°F)
Storage temperature
-40°C to +70°C
(-40°F to +158°F)
Over temperature shutdown
+50°C
(+122°F)
Operating humidity
15% to 80% RH (non-condensing)
Storage humidity
8% to 80% RH (non-condensing)
Operating altitude
3100 m max
(10000 ft max)
Storage altitude
4600 m max
(15000 ft max)