Installation, Manual mode auto test, Mode switching summary – Heath Zenith DualBrite Motion Sensor Light Control 5797 User Manual

Page 2: Timer, Lamp modes

Advertising
background image

2

598-1315-02

INSTALLATION

For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4
m) above the ground.

NOTE: If fixture is mounted higher

than 8 ft. (2.4 m), aiming the sensor down will reduce
coverage distance.
CAUTION: Keep the sensor at least 2" (51 mm)
away from the lamps.

CAUTION: To Avoid Fire Or Burn Hazards:

• Allow fixture to cool before touching. The bulb and the

fixture operate at high temperatures.

• Keep fixture at least 2" (51 mm) from combustible ma-

terials. Do not aim at objects closer than 3 feet. (1 m).

• Use only T4, 100W (max.) G8 bi-pin tungsten halogen

120 VAC lamps.

For eave mount only:

For under eave installation, the sensor head must
be rotated
as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
Also

for proper under eave operation, remove the

protective backing from the light shield and stick on as
shown below.

MANUAL MODE

... back on.

1 Second OFF

then...

Move ON-TIME Switch to

1, 5, or 20 minutes

Mode Switching Summary

Flip light switch

off for one second

then back on*

MANUAL MODE

AUTO

TEST

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

ON-TIME

RANGE

DU

AL BRIT

E™

MIN

MAX

TE

ST 1

5

20

MI

NUTE

S

OFF 3

6 DUS

K TO

H

OUR

DAWN

LA

MP

MOD

E

NO

RMAL S

OFT FL

ASH

Swing the sensor head towards the clamp screw

joint.

If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.

Then rotate the sensor head clockwise 180° so the

controls face down.

Controls

Controls

Controls

Clamp Screw

D

ual

B

rite

®

Timer

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.

Lamp Modes

There are three lamp modes (light turn-on effects) avail-
able when motion is detected:

NORMAL - Light instantly comes on.

SOFT - Light starts dim and gradually increases to
full brightness. Light gradually dims to half-bright,
pauses, and then continues dimming to off when
motion is no longer detected and after selected ON-
TIME.

FLASH - Light flashes on then off twice before turn-
ing on full brightness.

Light Shield

Opening

Advertising