Hitachi CP-X3010N User Manual

Page 27

Advertising
background image

27

Names

Operation Type

Header

Command Data

CRC

Action

Type

Setting Code

REMOTE FREQ.

HIGH

Set

OFF

BE EF 03

06 00

03 3C

01 00

31 26

00 00

ON

BE EF 03

06 00

93 3D

01 00

31 26

01 00

Get

BE EF 03

06 00

30 3C

02 00

31 26

00 00

MY IMAGE

Set

OFF

BE EF

03

06 00

3A C3

01 00

00 35

00 00

IMAGE-1

BE EF

03

06 00

AA C2

01 00

00 35

01 00

IMAGE-2

BE EF

03

06 00

5A C2

01 00

00 35

02 00

IMAGE-3

BE EF

03

06 00

CA C3

01 00

00 35

03 00

IMAGE-4

BE EF

03

06 00

FA C1

01 00

00 35

04 00

Get

BE EF

03

06 00

09 C3

02 00

00 35

00 00

MY IMAGE IMAGE-1

Delete

Execute

BE EF

03

06 00

71 C3

06 00

01 35

00 00

MY IMAGE IMAGE-2

Delete

Execute

BE EF

03

06 00

35 C3

06 00

02 35

00 00

MY IMAGE IMAGE-3

Delete

Execute

BE EF

03

06 00

C9 C2

06 00

03 35

00 00

MY IMAGE IMAGE-4

Delete

Execute

BE EF

03

06 00

BD C3

06 00

04 35

00 00

RS-232C Communication / Network command table (continued)