D/g-04 troubleshooting, Cavitation, Drop in volume or pressure – HP G-04 User Manual

Page 17: Pump runs rough, Premature failure of diaphragm, Water (or process fluid) in oil reservoir, Strong water (or process fluid) pulsations

Advertising
background image

17

D04-991-2400 5/1/04

D/G-04 Troubleshooting

Cavitation

•

Inadequate fluid supply because:
— Inlet line collapsed or clogged

— Clogged line strainer
— Inlet line too small or too long

— Air leak in inlet line
— Worn or damaged inlet hose

— Suction line too long
— Too many valves and elbows in inlet line

•

Fluid too hot for inlet suction piping system.

•

Air entrained in fluid piping system.

•

Aeration and turbulence in supply tank.

•

Inlet vacuum too high (refer to “Inlet Calculations”, page 3).

Symptoms of Cavitation

• Excessive pump valve noise

• Premature failure of spring or retainer
• Volume or pressure drop

• Rough-running pump
• Premature failure of diaphragms

Drop in Volume or Pressure

A drop in volume or pressure can be caused by one or more of
the following:

•

Air leak in suction piping

•

Clogged suction line or suction strainer

•

Suction line inlet above fluid level in tank

•

Inadequate fluid supply

•

Pump not operating at proper RPM

•

Relief valve bypassing fluid

•

Worn pump valve parts

•

Foreign material in inlet or outlet valves

•

Loss of oil prime in cells because of low oil level

•

Ruptured diaphragm

•

Cavitation

•

Warped manifold from overpressurized system

•

O-rings forced out of their grooves from overpressurization

•

Air leak in suction line strainer or gasket

•

Cracked suction hose.

•

Empty supply tank

•

Excessive aeration and turbulence in supply tank

•

Cavitation

•

Abrasives in the fluid

•

Valve incompatible with corrosives in the fluid

•

Pump running too fast

•

Worn and slipping drive belt(s)

•

Worn spray nozzle(s)

Pump Runs Rough

•

Worn pump valves

•

Airlock in outlet system

•

Oil level low

•

Wrong weight of oil for cold operating temperatures (change

to lighter weight)

•

Cavitation

•

Air in suction line

•

Restriction in inlet/suction line

•

Hydraulic cells not primed after changing diaphragm

•

Foreign material in inlet or outlet valve

•

Damaged diaphragm

•

Fatigued or broken valve spring

Premature Failure of Diaphragm

•

Frozen pump

•

Puncture by a foreign object

•

Elastomer incompatible with fluid being pumped

•

Pump running too fast

•

Excess pressure

•

Cavitation

Water (or Process Fluid) in Oil
Reservoir

•

Condensation

•

Ruptured diaphragm

•

Hydraulic cell not properly primed after diaphragm

replacement

•

Frozen pump

Strong Water (or Process Fluid)
Pulsations

NOTE: Small pulsations are normal in single-acting pumps
with multiple pumping chambers.

•

Foreign object lodged in pump valve

•

Loss of prime in hydraulic cell because of low oil level

•

Air in suction line

•

Valve spring (8) broken

•

Cavitation

•

Aeration or turbulence in supply tank