Installation, H1 h v – Hampton Direct H15-LP1 User Manual

Page 15

Advertising
background image

Hampton

®

H15-1 Direct Vent Freestanding Gas Stove

15

H1

H

V

Horizontal Venting with Two (2) 90

o

Elbows

Option V

H + H1

A)

1' Min. 3' Max.

B)

2' Min. 4' Max.

C)

3' Min. 5' Max.

D)

4' Min. 6' Max.

E)

5' Min. 7' Max.

F)

6' Min. 8' Max.

Horizontal Venting with Two (2) 90

o

Elbows

Option H

V

H + H1

A)

1' Max. 1' Min. 3' Max.

B)

2' Max. 2' Min. 5' Max.

C)

3' Max. 4' Min. 6' Max.

D)

4' Max. 6' Min. 7' Max.

E)

5' Max. 8' Min. 8' Max.

With these options, max.
total pipe length is 30 feet
with min. of 8 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90

o

elbows is

required.

With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90

o

elbows

is required.

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.

H

H1

V

Vent restrictor position A (fully open), refer to the "Vent
Restrictor Postion" section.

Vent restrictor position A (fully open), refer to the "Vent
Restrictor Postion" section.

Lengths do not include elbow indicated

Lengths do not include elbow indicated

INSTALLATION

Advertising
This manual is related to the following products: