Heat & Glo Fireplace XLR-PLUS-PB-AU User Manual
Page 28
Advertising

Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. o • 1/13
28
Figure 7.8
H
1
V
1
V
2
Top Vent - Vertical Termination
Venting with 2 elbows
Note: Use SLP Series
components only.
V
1
Minimum
H Maximum
V
2
V
1
+ V
2
Minimum
90° Elbow
2 ft. (610 mm)
*
*
6 in. (152 mm)
3 ft. (914 mm)
*
*
18 in. (457 mm)
5 ft. (1.5 m)
*
*
36 in. (914 mm)
7 ft. (2.1 m)
*
*
43 in. (1.1 m)
15 ft. (4.6 m)
*
*
H Max. = 15 ft. (4.6 m)
V
1
+ V
2
+ H Max. = 40 ft. (12.2 m)
* No specific restrictions on this value EXCEPT V
1
+ V
2
+ H cannot exceed 12.2 m
Note: All appliances that will burn butane must have
a 12 in. (305 mm) vertical section of pipe before
any other venting.