Henny Penny CBC/CBR-105 User Manual

Page 3

Advertising
background image

Model CBC/CBR-103,104,105,106,107

303

2-3

2-4. LOCATION

Place the cold bases in an area where product can be loaded and
unloaded without interruption. For proper operation, level the unit
by adjusting the bolts under the base, and leave 3 feet (91.44 cm)
clearance behind the unit for ventilation and service.

For maximum efficiency, units should be operated in an air-condi-
tioned environment, with maximum air temperature of 75° F
(24° C), and 55% relative humidity.

Wait at least 4 hours before plugging the unit into an
electrical supply. The gases and oils in the refrigeration
system need to settle before operating the compressor, or
damage to the compressor could result.

INFORMATION

High Low

CBC-103

R22

2.5 lbs (1.134 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

CBC-104

R22

2.5 lbs (1.134 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

UL Specs

CBC-105

R22

2.5 lbs (1.134 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

CBC-106

R22

2.5 lbs (1.134 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

CBC-107

R22

2.5 lbs (1.134 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

CBC-103

R134A

1.76 lbs (0.800 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

CBC-104

R134A

2.20 lbs (1.00 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

CE Specs

CBC-105

R134A

2.65 lbs (1.200 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

CBC-106

R134A

3.09 lbs (1.400 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

CBC-107

R134A

3.53 lbs (1.600 kg)

440psig

162 psig

(30.3 bar) (11.2 bar)

2-6. DRAIN CONNECTION

The cold bases-remote (CBR), require 1 inch (25.4 mm) drain
connection. Cold bases with condensing units (CBC) do not
require a plumbed drain.

2-5. REFRIGERATION

Refrigerant Type Amount of Refrig. Design Pressure

Advertising
This manual is related to the following products: