Hitachi 8755H User Manual

Page 11

Advertising
background image



ENGLISH

Please check and clean the air filter periodically. When the indicators or a message

prompts you to clean the air filter, comply with it as soon as possible. The air filter has two

kinds of filters inside. Replace the filters when they are damaged or too soiled. To prepare

the new filters, contact to your dealer and tell the following type number.

Type number : MU05611

When you replace the lamp, please replace the air filter.

An air filter of specified type will come together with a

replacement lamp for this projector.

.

Turn the projector off, and unplug the power cord. Allow

the projector to sufficiently cool down.

2.

Use a vacuum cleaner on and around the filter cover.

3.

Pull the filter cover knobs while lifting it, to take the filter

unit off.

4.

Use a vacuum cleaner for the filter vent of the projector

and both sides of the filter unit.

If the filters are damaged or too soiled, replace them according

to the following procedure number 5 to 7. Otherwise, please

jump to the procedure number 8.

5.

Pull the filter frame’s knob up while holding the filter

cover to remove the filter frame, then take the filters out.

6.

Set new filters where former filters were. Put the larger

meshed filter into a filter cover first. Then put the finer

meshed filter on the larger meshed one.

7.

Put the filter frame back where it was.

8.

Put the filter unit back into the projector.

9.

Turn the projector on and reset the filter time using the

FILTER TIME item in the EASY MENU.

(1) Press the MENU button to display a menu.

(2) Point at the FILTER TIME using the ▼/▲ button, then press the ► button. A dialog will appear.

(3) Press the ▲ button to select RESET on the dialog. It performs resetting the filter time.

Cleaning and replacing the air filter

WARNING ►Before taking care of the air filter, make sure the power cable

is not plugged in, then allow the projector to cool sufficiently.

►Use only the air filter of the specified type. Do not use the projector without the

air filter or the filter cover. It could result in a fire or malfunction to the projector.

►Clean the air filter periodically. If the air filter becomes clogged by dust or the like,

internal temperatures rise and could cause a fire, a burn or malfunction to the projector.

NOTE • Please reset the filter time only when you have cleaned or replaced

the air filter, for a suitable indication about the air filter.

• The projector may display the message such as “CHECK THE AIR FLOW” or

turn off the projector, to prevent the internal heat level rising.

Filter cover

Filter cover knobs

Filter unit

Filter cover

Filter frame

Filter (finer meshed)

Filter (larger meshed)

Advertising
This manual is related to the following products: