Consult the designs in the front pages referenced in the text by

alphabet letters. Closely follow the instructions set out in this

manual. All responsibility, for any eventual inconveniences, damages

or fires caused by not complying with the instructions in this manual,

is declined.

The cooker hood must be placed at a minimum distance of 50 cm from

the cooking plane for electric cookers and 65cm for gas or mixed

cookers.

If the appliance is installed above a gas cooking device with installation

instructions specifying a greater clearance, you must take this into

account.

Do not tile, grout or silicone this appliance to the wall. Surface

mounting only.

The hood is equipped with a top air outlet B for discharge of fumes to

the outside (Ducting version – exhaust pipe and pipe fixing clamps

not provided).

Should it not be possible to discharge cooking fumes and vapour to the

outside, the hood can be used in the filter version, fitting an activated

carbon filter and the deflector F

on the support (bracket) G, fumes and vapours are recycled through

the top grille H by means of an exhaust pipe connected to the top air

outlet B and the connection ring mounted on the deflector F (exhaust

pipe and pipe fixing clamps not provided).

The models with no suction motor only operate in ducting mode, and

must be connected to an external suction device (not supplied).

Installation - Fig. 4

Preliminary information for installation of the hood:

Disconnect the hood during electrical connection, by turning the home

mains switch off. Expansion wall plugs are provided to secure the

hood to most types of walls/ceilings. However, a qualified technician

must verify suitability of the materials in accordance with the type of

wall/ceiling. The wall/ceiling must be strong enough to take the weight

of the hood.

Do not tile, grout or silicone this appliance to the wall. Surface

mounting only.

Do not fix chimney flue to furniture or fly over shelves unless the

chimney flue can be easily removed, in case maintenance is

ever required.

Where foreseen remove the grease collecting panels.

Remove the grease filter/s

Do not tile, grout or silicone this appliance to the wall. Surface

mounting only. Do not fix chimney flue to furniture or fly over shelves

unless the chimney flue can be easily removed, in case maintenance

is ever required.

=

=

X

X

H

=

=

X

F

F

G

G

Assembling the chimney flue support/bracket (3 parts):

The three parts should be fixed with 4 screws, the support extension

is adjustable and should correspond to the internal width of the

telescopic chimney flue.

Assembling the deflector (only when a deflector composed of

3 parts is supplied – the deflector should be only for the filter

version):

The three parts should be fixed with 2 screws, the deflector extension

is adjustable and should correspond to the width of the chimney flue

support, to which it is then fixed.

1. Using a pencil, draw a line on the wall, extending up to the ceiling,

to mark the centre. This will facilitate installation.

2. Rest the drilling template against the wall: the vertical centre line

printed on the drilling template must correspond to the centre line

drawn on the wall, and the bottom edge of the drilling template

must correspond to the bottom edge of the hood: bear in mind

that, when installation is complete, the underside of the hood

must be at least 50 cm above the cooker top in the case of electric

cookers, and at least 65 cm above the cooker top in the case of

gas or mixed cookers.

3. Rest the support bracket on the drilling template so that it

coincides with the dotted rectangle, mark the two outer holes and

drill them, remove the drilling template, insert 2 wall plugs and fix

the hood support bracket into place using two 5x45mm screws.

4. Hang the hood on the bracket.

5. Adjust the distance of the hood from the wall.

6. Adjust the horizontal position of the hood.

7. Using a pencil mark the cooker hood permanent drill hole inside

the suction group (two drill holes are necessary for fastening).

8. Remove the hood from the bracket.

9. Drill at the point marked (Ø8mm - see operation 7).

10. Insert 2 wall plugs.

11. Rest the chimney support bracket „G“ against the wall, touching

the ceiling. Use the support bracket as a drilling template (the

small slot formed on the support must coincide with the line drawn

on the wall as above – operation 1) and mark 2 holes with a pencil,

drill the holes (Ø8mm), insert 2 wall plugs.

12. Fix the chimney support bracket to the wall using two 5x45mm

screws.

13. Hook the hood onto the bottom bracket.

14. Fix the hood into its final position on the wall (ABSOLUTELY

ESSENTIAL).

15. Connect a pipe (pipe and pipe clamps not provided, to be

purchased separately) for discharge of fumes to the connection

ring located over the suction motor unit.

If the hood is to be used in ducting version, the other end of the

pipe must be connected to a device expelling the fumes to the

outside. If the hood is to be used in filter version, then fix the

deflector F to the chimney support bracket G and connect the

other extremity of the pipe to the connection ring placed on the

deflector F.

16. Make the electrical connections.

17. Apply the chimney stacks and fasten them at the top to the

chimney support „G“ (17b) using 2 screws (17a).

18. Slide the bottom section of the chimney down until it completely

covers the suction unit and slots into the housing provided on top

of the hood.

Replace the grease filter/s (and where foreseen the grease collecting

panels) and check that the hood is operating correctly.

Electrical connection

The electrical tension must correspond to the tension noted on the

label placed inside the cooker hood. Connect the electrical plug,

where provided, to the an easily accessible outlet in conformity with

local standards in force.

Where an electrical plug is not provided (for direct connection to

electrical network) place a standards approved bipolar switch with an

aperture distance of not less than 3mm (accessible) from the contacts.

Advertising